Name | POWER SOURCE | Model | 2L-DC | Input Voltage | AC100/220V | Feature | Current input unit and power supply | output | DC 24V 200mA | Function | (4~20mA) Power supply for indication | SIZE | 49×61×98 (H×W×D) | Model |
| 2L-LI |
| Input Voltage |
| AC 220V |
| Contact Point Capacity |
| 0~300Ω / 4~20mA (Separate Order) Voltage Outpu0~1.5V(%) |
| Feature |
| Digital Indicator without separate uinit ( Built-in Panel Meter Amplifier) |
| Function |
| Indicator for various kids of tanks |
| Panel CUT |
| 100 Φ |
| SIZE |
| 110×110×92 |
| Material |
| - HEAD - Nylon Fiber - FLOAT- P/P foaming - PIPE - SUS 304 | |
| Model |
| 2L-SC |
| Input Voltage |
| AC 220V |
| output |
| 4~20mA Voltage Outpu0~1.5V(%) |
| Input |
| Resistance Input (0~300Ω) |
| Function |
| Indicator for various kids of tanks |
| SIZE |
| 49×61×98 (H×W×D) |
| Material |
| - HEAD - Nylon Fiber - FLOAT- P/P foaming - PIPE - SUS 304 | | |
| ▶ | 2L-LI is the Float-type of Level Indicator and it can indicate Spot and Panel as 2 Line (Not necessary for Shield Line) between sensor and unit. Not necessary for separate unite. Unit inside of Panel Indicating Meter is built in. | |
| ▶ | Various kinds of water tanks, Oil tank, Waterpurification tank, Expansion tank, Condenser tank, Pressure tank, Booster tank, Waste water tank, etc | | | | | | | | | | |
| ▣ | Fill the existence of pressure such as non-pressure tank, pressure tank(less than 5 kg) according to the classes of tanks and separate entry is required if temperature is high (more than 80℃). (Special order in case of more than 5K) | ▣ | There are two types; Flange and Screw type. In case of a Flange type, it should use with 3″(80Φ)4″(100Φ), In case of a Screw type, 2″(50Φ) socket should be welded to a tank. | ▣ | Separate order is required for special chemicals and high temperature use. (80℃ and more) | | Attention : Separate order is required for special chemicals and high temperature use | | Gear-type Sensor | Flexible Sensor | ◆ | As Gear-type sensor hasn't the height of ceiling, it is ordered and manufactured as a Gear-type when sensor isn't able to put in a tank. | ◆ | Refer to the Gear-Type in the tail of 35~36 page | ◆ | Temperature should be less than 80℃ only (Oil, Water, etc). | ◆ | Special order is required for the chemicals tank such Hydrochloric acid, Sulphuric acid | | | | [Attention!] Never use to a Pressure tank | | ◆ | As Flexible-type sensor hasn't the height of ceiling, it is ordered and manufactured as a Flexible-type when sensor isn't able to put in a tank. | ◆ | In the lower part of sensor, the stain weight is an one-touch fitting. Simple to put a hose in (50mm/m socket-type). | ◆ | When handling a sensor, Put a stain weight in first and continue to put with care while remaining a sensor as the original position. (Be careful not to be bent) | ◆ | When delivering, deliver as a fixed position to the handling frame (PVC Pipe) and Do not give an impulse or throw. (It can be the reason of damage) | ◆ | Temperature should be less than 80℃ only (Oil, Water, etc) | | [Attention!] Never use to a Pressure tank. | | | |