| | | · | HIMAP applied a 32Bit DSP processor which can speedily process data and offer 2 RS485-a port. For up level monitoring system. - Dialog based menu and setting - Protective relay function (OCR, OCGR, SGR, DGR, OVR, OVGR, UVR, MPR, DFR) - Measuring (Digital Meter, V, A, kW, kVAR, kWH, kVARH, PF, HZ) - Communication - Self-diagnostic - Power interruption - Fault recording - Event recording - OE function - Harmonic filter - Various protocol support | | | | | Description | Specification | Rating | Current | 1A or 5A, Burden : 0.1VA/Phase | Voltage | 110V or 190V, Burdon : 0.1VA/Phase | Frequency | 50Hz or 60Hz | Accuracy | Meter | ±1.0% | Relay | ±5.0% | Temperature | Operation Guarantee | -10℃~55℃ | Storage Guarantee | -25℃~70℃ | Insulation | Between Circuit - Ground | 10㏁ | Between Circuit - Circuir | 5㏁ | Between Output Relay | 5㏁ | Dielectric Withstand | Power-Frequency Withstand | AC 60Hz 2000V/1Min | Lightning Impulse Withstand | 1.2/50㎲ 5KV | Overload Withstand | Current Circuit | Rated Current × 3 : 3 hours Rated Current × 20 :2 second | Voltage Circuit | Rated Voltage × 3 : 3 hours | Control Power | Rated Voltage × 1.3 : 3 hours | Control Power Interruption | Max. 500ms | Control Power Supply | AC/DC 95V~250V 50/60Hz | Applicable Standard | IEC 60255 / KEMC 1120 | | | | · | Hyundai HIMAP-BC is a bay control unit based on the microprocessors and integrates with the new technology of electrical, electronic and mechanical field of Hyundai. | | | | | Description | Specification | Rating | Current | 1A or 5A, Burden : 0.1VA/Phase | Voltage | 110V or 190V, Burdon : 0.1VA/Phase | Frequency | 50Hz or 60Hz | Accuracy | Meter | ±1.0% | Relay | ±5.0% | Temperature | Operation Guarantee | -10℃~55℃ | Storage Guarantee | -25℃~70℃ | Insulation | Between Circuit - Ground | 10㏁ | Between Circuit - Circuir | 5㏁ | Between Output Relay | 5㏁ | Dielectric Withstand | Power-Frequency Withstand | AC 60Hz 2000V/1minute | Lightning Impulse Withstand | 1.2/50㎲ 5kV | Overload Withstand | Current Circuit | Rated current × 3 : 3 hours Rated current × 20 :2 second | Voltage Circuit | Rated voltage × 3 : 3 hours | Control Power | Rated voltage × 1.3 : 3 hours | Control Power Interruption | Max. 500ms | Control Power Supply | AC/DC 95V~250V 50/60Hz | Applicable Standard | IEC 60255 / KEMC 1120 | | | | · | HIMIX(Hyundai Intelligent Measuring Instrument Box) is designed for an external display unit of the HIMAP and to ensure a simple, easy, intuitive operation and maintenance of switchgear panel.
| · | It can be done by RS 485 9600bps communication. Rear port of HIMIX and C3 is used for communication.
| · | HIMIX is composed with following parts. 1) Digital display FND - Ampere meter (Ir, Is, It, In) - Volt meter (Vrs, Vst, Vtr, Vn) - Power meter (KVA, KW, KVAR, KWH, KVARH, PF, HZ) 2) Circuit breaker status Lamp 3) Manual operation switch 4) Operating mode select lever 5) Selected point indicator(LED) 6) Comm.Status with HIMAP indicator (LED) 7) Intuitive terminal block of Rear side. | | |