zui大工作壓力: | 712.15.160 Cryo Gauge(Mpa) | 型號: | 712.15.160 Cryo Gauge |
適用范圍: | 低溫冷凍行業 | 精度等級: | 1.6 |
品牌: | WIKA/威卡 | 加工定制: | 是 |
量程范圍: | 0-140 to 4000mbar(kPa) | 外形尺寸: | 160(mm) |
WIKA 712.15.160 Cryo Gauge®
低溫冷凍行業用全鋼差壓壓力表
Differential pressure gauge
Model 712.15.160, Cu-alloy
Model 732.15.160, stainless steel version
Differential pressure gauge
Model 712.15.160, Cu-alloy
Model 732.15.160, stainless steel version
Applications
Level measurements in closed tanks, particularly in cryotechnology
Filter monitoring
Monitoring and control of pumps
For gaseous and liquid media that are not highly viscous or crystallising and have no suspended solids
Special features
Differential pressure measuring ranges from 0 … 40 mbar to 0 ... 4,000 mbar
High working pressure (static pressure) of 50 bar
Overpressure safety either side up to 50 bar
Scaleable measuring ranges (maximum Turn Down of 1 : 3.5)
Very compact design
Optionally compact valve manifold with working pressure
Description
These high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks.
With only 6 different measuring cells all usual tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270 degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and easily.
An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument.
The level display can be supplied with an optional, integrated 4 … 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure can be retrofitted on site.
The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.
Design and operating principle
Pressures p1 and p2 act on the media chambers ⊕ and ?, which are separated by an elastic diaphragm (1).
The differential pressure (Δp = p1 - p2) leads to an axial deflection of the diaphragm against the measuring range spring (2).
The deflection, which is proportional to the differential pressure, is transmitted to the movement (5) in the indicating case (4) via a pressure-tight and low friction lever mechanism (3).
Overpressure safety is provided by metal bolsters (6) resting against the elastic diaphragm.
Standard version
Differential pressure gauge
Model 712.15.160
Model 732.15.160
Illustration of the principle
Mounting according to affixed symbols
⊕ high pressure and ? low pressure
Span adjustment
The measuring span of the differential pressure gauge can, depending on the particular measuring cell used, be adjusted within the measuring range limits given in the previous specifications table. Ideally, this adjustment should be made on a test bench, though it can also be carried out at the measuring point using a hand test pump.
The span adjustment, situated at the 4 o‘clock point on the case circumference, is accessible by removing the cover cap. With the gauge subject to the desired nominal pressure, insert a hexagon screwdriver (SW 3 mm) into the funnel guide, and adjust the pointer to the final value by turning it clockwise (for a lower measuring range) or anti-clockwise (for a greater measuring range). The gauge will then be fully adjusted to the required measuring range. If the gauge is equipped with a transmitter model 89x.44, then this procedure will also adjust the output signal to the new measuring range. After completing the adjustment the instrument should be re-sealed with the cover cap.
Scale designs
The dials can be made to customer‘s requirements and also with multiple scales. In addition, up to three different, interchangeable slip-on dials can be supplied, e.g. for measuring different media.
These can be printed with all usual units on them, e.g. kg, litre, m3, mmH2O, inchH2O, % etc.. Red marks for maximum fill level, customer logos and other custom printing are likewise possible. If desired, we can carry out the calculation for the tank fuel level from drawings of the tank geometry, and then make the appropriate scales.
Dimensions in mm
CE conformity
EMC directive
2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application)
ATEX directive 1)
94/9/EC, II 2 G Ex ia IIC 1) Option
Approvals
GOST-R, import certificate, Russia
GOST, GOST, metrology/measurement technology,
Russia (only for model 712.15.160)
BAM, oxygen application (only for model 732.15)
Approvals and certificates, see website
Option
Valve manifold (wetted)
with mounted working pressure gauge
With a single order, all parts necessary for the fitting to the differential pressure gauge are included in the delivery: 4 x hexagon screws M8 x 16 , 2 x O-ring seal
Option
Switch contacts
for level and/or working pressure indicators
A modular system of electromechanical and electronic switch contacts with plug connection, also suitable for retrofitting on site, can be fitted both to the level display and to the working pressure indication. They consist of self-contained units, which can be fitted to any pointer pressure gauge within a few minutes. The connection to the instrument pointer is made by means of a special yoke so that a carrier pin at the pointer itself is not needed. The set value pointer of the
installed switch contacts are adjusted, from the outside, to the value at which the switching operation is to take place, using the adjustment lock with a separate or integral key. A coupler connector, an M3 x 20 centring screw and a seal are
included in the delivery.
Switching functions
The following applies, as a general rule, to the contact functions of the model 828 1) magnetic snap-action contacts in connection with our standard settings:Index 1 according to the contact type no. means:
Contact closes the circuit when the set point is exceeded Index 2 according to the contact type no. means:
Contact opens the circuit when the set point is exceeded Index 3 according to the contact type no. means:
When the set value is exceeded, one circuit is opened and one circuit is closed simultaneously (change-over contact)
The following applies, as a general rule, to the contact functions of the model 838 1) inductive contacts in connection with our standard settings:
Index 1 according to the contact type no. means:
Contact closes the control circuit when the set point is exceeded (flag disengages from control head)
Index 2 according to the contact type no. means:
Contact opens the control circuit when the set point is exceeded (flag engages with control head)
The switching functions are based on a clockwise rotational motion of the instrument pointer.
Dimensions in mm
Option
Panel mounting
Ordering information
Model / Scale range (measuring cell) / Scale design / Process connections with centre distance / Options