1、 輸入激勵:恒壓:10VDC(或5VDC)
2、 輸入阻抗:6 KΩ~20KΩ
3、 輸出阻抗:2.5 KΩ~6 KΩ
4、 絕緣電阻:≥100MΩ(50VDC電壓)
5、 絕緣電壓:在殼體和引線之間500VDC或500VAC
6、 過載壓力:3倍滿量程或50Mpa(取兩者zui小壓力值)
7、 被測介質相容性:與316不銹鋼兼容的氣體和液體
8、 響應時間:(10~90%)≤1ms
9、 補償溫度:0~70℃
10、 工作溫度:-20~70℃
11、 儲存溫度范圍:-40~100℃
LX19V
LX13V
型號 | LX13V LX15V | LX19V LX24V | LX20V | 單位 | |||
LX26V LX30V | |||||||
量程范圍 | 350KPa | 50Psi | 35Kpa | 5Psi | 35KPa | 5Psi | |
700KPa | 100Psi | 70kpa | 10Psi | 70KPa | 10Psi | ||
1MPa | 150Psi | 100kpa | 15Psi | 100KPa | 15Psi | ||
2MPa | 300Psi | 200kpa | 30Psi | 200KPa | 30Psi | ||
3.5MPa | 500Psi | 350KPa | 50Psi | 350KPa | 50Psi | ||
7MPa | 1000Psi | 700KPa | 100Psi | 700KPa | 100Psi | ||
10MPa | 1500Psi | 1MPa | 150Psi | 1MPa | 150Psi | ||
20MPa | 3000Psi | 2MPa | 300Psi | 2MPa | 300Psi | ||
35MPa | 5000Psi | 3.5MPa | 500Psi | 3.5MPa | 500Psi | ||
| | 7MPa | 1000Psi | | | ||
| | 10MPa | 1500Psi | | | ||
| | 20MPa | 3000Psi | | | ||
| | 35MPa | 5000Psi | | | ||
非線性、重復性、遲滯 | |||||||
非線性 | |||||||
(0~70)KPa | zui小值 | 典型值 | zui大值 | %FS | |||
(0.1~35)MPa | ±005 | ±0.15 | ±0.3 | %FS | |||
(3.5~35)MPa | ±005 | ±0.15 | ±0.3 | %FS | |||
重復性及遲滯 | ±0.02 | ±0.05 | ±0.1 | %FS | |||
輸出特性 | |||||||
零位輸出 | -2 | 0 | 2 | mVDC | |||
滿量程輸出 | |||||||
(0~70)KPa | 48 | 50 | 52 | mVDC | |||
(0.1~35)MPa | 80 | 100 | 120 | mVDC | |||
溫度特性 | |||||||
零位溫度誤差 | |||||||
(0~70)KPa | | ±0.5 | ±1 | %FS | |||
(0.1~35)MPa | | ±0.5 | ±1 | %FS | |||
滿量程溫度誤差 | |||||||
(0~70)KPa | | ±1 | ±1.5 | %FS | |||
(0.1~35)MPa | | ±1 | ±1.5 | %FS | |||
阻抗特性 | |||||||
輸入阻抗 | 6 | 12 | 20 | KΩ | |||
輸出阻抗 | 2.5 | 5 | 6 | KΩ |