鍋爐水處理劑報價鍋爐水處理劑報價(船用AUTOTREAT 25 LTR/桶) 型號:698720-AUTOTREAT - 25 LTR庫號:M203224
698720 AUTOTREAT - 25 LTR
NALFLEET™ AUTOTREAT™ is a multifunctional, liquid boiler water treatment, formulated with alkaline compounds, scale inhibitor, dispersant, and volatile amines for the protection of the feed, boiler and condensate systems. NALFLEET™ AUTOTREAT™ 是一種多功能液體鍋爐水處理劑,具有堿性化合物,阻垢劑,分散劑和揮發性胺,可用于保護飼料,鍋爐和冷凝水系統。 該產品結合了磷酸鹽處理和新的聚合物技術。這可確保沉淀物保持柔軟不粘附,易于通過排污去除。
產品特性
•液體鍋爐水處理化學品,簡化了計量和處理
•適用于所有鍋爐,壓力高達30 bar
• 含有揮發性胺,可中和冷凝水系統中的酸
•分散劑作用可懸浮污泥和沈積物顆粒,通過排污去除污泥和沈淀物顆粒
•保持鍋爐管表面清潔,促進傳熱條件
•測試簡單,確保含藥量水平
•多功能鍋爐水處理
• 防止結垢和腐蝕,提高系統壽命和性
Product Number Product name
698720 AUTOTREAT - 25 LTR
Product Number Product name Description
739490 SPECTRAPAK 315 P Alkalinity,Chloride and pH
Supplementary Test Kits
698746 SPECTRAPAK 313 DEHA
555490 SPECTRAPAK 312 Hydrazine
574913 SULPHITE TEST KIT Sulphite
使用說明
NALFLEET™Autotreat是一種鍋爐水調節器,設計用于與氧氣清除劑配合使用時對船舶鍋爐系統的保護。該產品將磷酸鹽處理與新的聚合物技術相結這確保沉淀物保持柔軟和不粘附,以便通過排污容易地除去。該產品應始終與氧氣清除劑一起使用,NALFLEET™氧氣清道夫加。請注意,該產品可與給水配合使用。
產品應連續配有自動加藥裝置。或者,可以通過旁路桶式進料器將產品進料到鍋爐進料管線中。
劑量和控制
初始填充劑量為2.4升NALFLEET™Autotreat /噸水鍋爐容量,達到P-堿度水平約。200 ppm。對于未經處理的系統,建議初使處理達到200ppm p-堿度的合適水平。下面給出的劑量圖是為了方便確定提高P-Alkalinity所需的產品量。請注意,該表基于達到200 ppm。
P-堿度 0 50 100 150 200 250 300 350
Dose in l/ton 2.4 1.8 1.2 0.6 0 0 0 Blow Down
P-堿度如ppm CaCO3.
這些是基于經驗的推薦值,
制造商規格或公司規定。典型的控制限制是:
• P-堿度: 150-300 ppm as CaCO3.
•氯化物: 200 ppm Cl max.
•冷凝水pH 8.3-9.0.
通過排污除去過量的氯化物。
采樣和測試
排污后始終從同一點取出,立即冷卻并測試。按照WSS測試套件說明進行操作,并將結果記錄在防水中。結果應按照防水說明中的說明發送至WSS 。
重要的是進行定期測試以確保水平正確。
Product information
This product supersedes product no: 777709
Autotreat combines well-known phosphate treatment with new polymer technology. This ensures that precipitates are kept soft and non-adherent for easy removal by blowdown.
Features
Liquid boiler water treatment chemical for simplified dosing and handling
Suitable for all boilers, up to 30 bar pressure
Contains volatile amines to neutralise acids occurring in condensate system
Dispersant action suspends sludge and sediment particles for efficient removal by blowdown
Keeps boiler tube surfaces clean, promoting the best heat transfer conditions
Simple testing to determine treatment level
Benefits
Multifunctional boiler water treatment
Prevents scaling and corrosion, increasing system life and reliability
Specification
General
Invent Hazard Material (IMO/EU) classification C-9
Physical properties
Appearance Light yellow
Density [g/ml] 1.1
Form Liquid
pH 13-14
Technical data
Not Compatible Avoid aluminium, zinc and galvanised steel.
Directions for use
NALFLEET™ Autotreat is a boiler water conditioner designed for optimum protection of ships boiler systems when used in conjunction with an oxygen scavenger. The product combines well known phosphate treatment with new polymer technology. This ensures that precipitates are kept soft and nonadherent for easy removal by blowdown. The product should always be used in conjunction with an oxygen scavenger, preferably NALFLEET™ Oxygen Scavenger Plus. Note that this product is formulated for use in conjunction with good quality feed water.
Dosing method
The product should preferably be dosed continuously with an automatic dosing unit. Alternatively the product can be fed into the feed line by means of a by-pass pot feeder.
Dosage and control
Initial fill dosage is 2.4 litres of NALFLEET™ Autotreat/ton of boiler capacity to reach a P-Alkalinity level of approx. 200 ppm. For an untreated system it is recommended to initially bring the treatment up to a suitable level of 200 ppm p-Alkalinity. The dosage chart given below is for convenience to determine the amount of product required to elevate P-Alkalinity. Note that the table is based on reaching 200 ppm.
These are recommended values based on experience, and are in no way intended to replace the boiler manufacturers specifications, or company regulations. Typical control limits are: * P-Alkalinity: 150-300 ppm as CaCO3. * Chlorides: 200 ppm Cl max. * Condensate pH 8.3-9.0. Excessive Chlorides are removed by blowdown.
Sampling and testing
A representative sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blowdown, cooled and tested immediately. Follow the WSS Test Kit instructions and log the results in Waterproof. The results should be sent to WSS as stated in the Waterproof instructions.
It is important that regular testing is carried out to ensure that treatment levels are correct.