HXVD-100VAC-2Z-NZ數顯電壓繼電器
系列型號:
S為單相,D為兩相,T為三相
HUVS-58VAC-2Z-NZ數顯電壓繼電器;
HUVS-100VAC-2Z-NZ數顯電壓繼電器;
HUVS-220VAC-2Z-NZ數顯電壓繼電器;
HUVS-380VAC-2Z-NZ數顯電壓繼電器;
HUVS-58VAC-2H-NZ數顯電壓繼電器;
HUVS-100VAC-2H-NZ數顯電壓繼電器;
HUVS-220VAC-2H-NZ數顯電壓繼電器;
HUVS-380VAC-2H-NZ數顯電壓繼電器;
HOVS-58VAC-2Z-NZ數顯電壓繼電器;
HOVS-100VAC-2Z-NZ數顯電壓繼電器;
HOVS-220VAC-2Z-NZ數顯電壓繼電器;
HOVS-380VAC-2Z-NZ數顯電壓繼電器;
HOVS-58VAC-2H-NZ數顯電壓繼電器;
HOVS-100VAC-2H-NZ數顯電壓繼電器;
HOVS-220VAC-2H-NZ數顯電壓繼電器;
HOVS-380VAC-2H-NZ數顯電壓繼電器;
HXVS-58VAC-2Z-NZ數顯電壓繼電器;
HXVS-100VAC-2Z-NZ數顯電壓繼電器;
HXVS-220VAC-2Z-NZ數顯電壓繼電器;
HXVS-380VAC-2Z-NZ數顯電壓繼電器;
HXVS-58VAC-2H-NZ數顯電壓繼電器;
HXVS-100VAC-2H-NZ數顯電壓繼電器;
HXVS-220VAC-2H-NZ數顯電壓繼電器;
HXVS-380VAC-2H-NZ數顯電壓繼電器;
HUVD-58VAC-2Z-NZ數顯電壓繼電器;
HUVD-100VAC-2Z-NZ數顯電壓繼電器;
HUVD-220VAC-2Z-NZ數顯電壓繼電器;
HUVD-380VAC-2Z-NZ數顯電壓繼電器;
HUVD-58VAC-2H-NZ數顯電壓繼電器;
HUVD-100VAC-2H-NZ數顯電壓繼電器;
HUVD-220VAC-2H-NZ數顯電壓繼電器;
HUVD-380VAC-2H-NZ數顯電壓繼電器;
HOVD-58VAC-2Z-NZ數顯電壓繼電器;
HOVD-100VAC-2Z-NZ數顯電壓繼電器;
HOVD-220VAC-2Z-NZ數顯電壓繼電器;
HOVD-380VAC-2Z-NZ數顯電壓繼電器;
HOVD-58VAC-2H-NZ數顯電壓繼電器;
HOVD-100VAC-2H-NZ數顯電壓繼電器;
HOVD-220VAC-2H-NZ數顯電壓繼電器;
HOVD-380VAC-2H-NZ數顯電壓繼電器;
HXVD-58VAC-2Z-NZ數顯電壓繼電器;
HXVD-100VAC-2Z-NZ數顯電壓繼電器;
HXVD-220VAC-2Z-NZ數顯電壓繼電器;
HXVD-380VAC-2Z-NZ數顯電壓繼電器;
HXVD-58VAC-2H-NZ數顯電壓繼電器;
HXVD-100VAC-2H-NZ數顯電壓繼電器;
HXVD-220VAC-2H-NZ數顯電壓繼電器;
HXVD-380VAC-2H-NZ數顯電壓繼電器;
HUVT-58VAC-2Z-NZ數顯電壓繼電器;
HUVT-100VAC-2Z-NZ數顯電壓繼電器;
HUVT-220VAC-2Z-NZ數顯電壓繼電器;
HUVT-380VAC-2Z-NZ數顯電壓繼電器;
HUVT-58VAC-2H-NZ數顯電壓繼電器;
HUVT-100VAC-2H-NZ數顯電壓繼電器;
HUVT-220VAC-2H-NZ數顯電壓繼電器;
HUVT-380VAC-2H-NZ數顯電壓繼電器;
HOVT-58VAC-2Z-NZ數顯電壓繼電器;
HOVT-100VAC-2Z-NZ數顯電壓繼電器;
HOVT-220VAC-2Z-NZ數顯電壓繼電器;
HOVT-380VAC-2Z-NZ數顯電壓繼電器;
HOVT-58VAC-2H-NZ數顯電壓繼電器;
HOVT-100VAC-2H-NZ數顯電壓繼電器;
HOVT-220VAC-2H-NZ數顯電壓繼電器;
HOVT-380VAC-2H-NZ數顯電壓繼電器;
HXVT-58VAC-2Z-NZ數顯電壓繼電器;
HXVT-100VAC-2Z-NZ數顯電壓繼電器;
HXVT-220VAC-2Z-NZ數顯電壓繼電器;
HXVT-380VAC-2Z-NZ數顯電壓繼電器;
HXVT-58VAC-2H-NZ數顯電壓繼電器;
HXVT-100VAC-2H-NZ數顯電壓繼電器;
HXVT-220VAC-2H-NZ數顯電壓繼電器;
HXVT-380VAC-2H-NZ數顯電壓繼電器;
用途
HXVD-100VAC-2Z-NZ數顯電壓繼電器主要用于繼電保護線路中,作為欠電壓或過電壓監視的動作元件。報警電壓
值可在產品啟動后進入菜單自行設備,且每相報警電壓設備相互獨立。輔助電源電壓一經饋入,綠色電壓指示燈亮,將被測電壓和設定值進行比較,若被監測電壓任意一相達到報警狀態,紅色報警指示燈閃爍提示報警,若被測電壓在延時時間內恢復,報警指示燈停止閃爍,輸出繼電器保持復位狀態;若超過設定的延時時間,輸入電壓還未恢復,輸出繼電器重位。
當發生報警助理輸出繼電器復位后,若所有被測電壓又恢復到正常狀態,此時紅色報警指示燈停止
閃爍,輸出繼電器復位。
多路監視顯示:U1燈亮,數碼管顯示U1端輸入電壓值;U2燈亮,數碼管顯示U2端輸入電壓值;U3燈亮,數碼管顯示U3端輸入電壓值;電壓顯示10S自動切換一次,也可以手動按“↑”和“↓”鍵切換。
技術參數
監測電壓范圍:10-500VAC 50HZ
輔助電源工作范圍:85-264VA或100-264VDC
測量誤差:≤1%
報警回差:5%
可調報警延時時間:0.2-10S
溫度誤差:≤0.03%/℃
功耗:≤5W
延遲時間:0.1-10S±1S
觸點容量:在電壓不大于250V時:觸點長期接通電流為5A;在電壓不大于250V時:電路時間常數L/R為5MS的直流電路中,觸點斷開容量為50W;在電壓不大于250V時:功率因數COSφ為0.4的交流電路中,觸點斷開容量為250VA
HXVD-100VAC-2Z-NZ數顯電壓繼電器規格型號:
HXVD-100VAC-2Z-NZ數顯電壓繼電器接線圖:
HXVD-100VAC-2Z-NZ數顯電壓繼電器外形尺寸圖:
上海約瑟電器有限公司以先進制造、能源礦產和高科技產業為核心,以投資業務為重點,打造核心競爭力,確立產業地位,以的品質和增值服務為基礎,為世界各地客戶創造價值。