北京康拉德科技有限公司
Funke TPL01-L-22-11 熱交換器
秒報價 FMI W5G45A23T451,Nr.36349 離心通風機
FMI W5G45A23T451,Nr.36349 離心通風機
FMS Force Measuring Systems AG LMGZ205.2000.25.S01.H29 壓力傳感器
Foedisch PFM 92c 煙氣分析儀
foerster 6.720.01-3701-12 探傷儀探頭
foerster 1394142,6.034.02-6707-11 探傷儀探頭
foerster PART—NO.6.461.01-2050 Order-660870 探傷儀用探頭
foerster 0416789 signertapparat V20 360 1008 3 噴槍
foerster 2.891.30-0110 探傷儀探頭
foerster 0154474,6.762.02-6621-2510 探傷儀用探頭
FOMET DMM-20T-EDDU 3/4 齒輪泵附件
FOMET 3P45T 齒輪泵
Fonovits TMIW-2 溫控器
Forkardt SDVN 25-100-0-0-D 工件夾具
Forkardt DF081220100, SDVN 25-50-0-0-D 工件夾具
Forkardt Deutschland GmbH SDN 8-25 Nr:DF080026000 液壓缸
FORM+TEST Seidner Order-no. B26660 硬度計
FORM+TEST Seidner Order-no. B26670 硬度計附件
FORSTHOFF MINI-Electronic, 1500 W, 230 V 超聲波焊槍
FORSTHOFF Heizelement 2007, 1500 W 焊槍附件
fortress ATSTOP024 感應傳感器
Foseco 24V/000002052 油壓傳動閥
Foseco 2052 油壓傳動閥
Foseco 1501 流量計
Foseco DK 47 R1/4 NPT 流量計
Foseco M90 L4 B14/1.5KW 000002035 電機3
Foseco 2187 油壓傳動閥
Foseco 1037
Foseco 1626 流量計
Foseco UK-040GML0030 流量計
Foseco 1634 壓力傳感器
Foseco 1037 油壓傳動閥
Foseco UCFL 208 000001571 油壓傳動閥附件
Bulletin #8400-571b
Description
For your convenience, Acromag offers several
mounting accessories to simplify your system
installation. Our 19” rack-mount kit provides a
clean solution for mounting your I/O modules
and a power supply. Or, you can buy pre-cut DIN
rail strips for mounting on any flat surface.
Ordering Information
NOTE: For more information visit .
Mounting Accessories
1025-673
Retro-fit mounting bracket for 150T-XJSM explosion-
proof housing (enables Flat Pack 250T mounting)
20RM-16-DIN
19” rack-mount kit with DIN rail
DIN RAIL 3.0
DIN rail strip, Type T, 3 inches (75mm)
DIN RAIL 16.7
DIN rail strip, Type T, 16.7 inches (425mm)
ESA-DIN-HMK
DIN rail horizonal mounting kit,
holds three EtherStax units.
ESA-DIN-VMK
DIN rail vertical mounting kit,
holds two EtherStax units.
ESA-OMK
Open circuit board EtherStax mounting kit,
stacks two units.
ESA-SMK
Surface mounting EtherStax kit,
mounts up to three units.
Simplifies mounting of Acromag I/O Modules
◆
Ideal for mounting in test stands and instrument racks
Mounting
Mounting kits, DIN rail strips and accessories
Accessories
ESA-DIN-VMK kit (vertical terminals).
ESA-DIN-HMK kit (horizontal terminals).秒報價 FMI W5G45A23T451,Nr.36349 離心通風機
ESA-SMK surface/machine mounting kit.
Rubber grommets dampen shock and
vibration
ESA-OMK open board stacking kit. One kit sup-
plies standoffs to stack two units.
Model 20RM-16-DIN
19” Rack Mount Kit
.
■
.
■
.
■
.
■
3.
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2010. Data subject to change without notice. Printed in USA 11/2010
Accessories
Mounting
Mounting kits, DIN rail strips and accessories
150T-XJSM-WM, 150T-XJSM-PM (retired products),
Explosion-Proof Housing Wall-Mount, Pipe-Mount
Replace original bracket with Part #1025-673
for mounting of Flat Pack 250T transmitters
1025-673 Mounting Bracket
For retro-fit of 150T explosion-proof housings with
Flat Pack instruments
1025-673
.
■
F
■
.
■
.
■
30765 S Wixom Rd, Wixom, MI 48393 USA
3-position:
L = 0.66 inches (16.9 mm)
6-position:
L = 1.26 inches (32.3 mm)
Spring Clamp Terminal Blocks
Barrier Strip Terminal Blocks
Standard
Cage Clamp T
erminal Blocks
3-position: L = 0.87 inches (22.3 mm)
6-position: L = 1.47 inches (37.7 mm)
Wi
re
range:
AWG #12-26
Wi
re
range:
AWG #12-26
Wi
re
range:
AW
G #12-28
.977
.550
.010
.144
.050
L
.022秒報價 FMI W5G45A23T451,Nr.36349 離心通風機
.200
.147
Dimensions in mm
Bulletin #8400-575
Description
These optional terminal blocks provide safe and
secure wiring connections. Large captive screw
terminals or spring clamps enable fast, easy
connections. Pluggable terminals are removable
for simple disconnection of the module without
disturbing the wiring.
Optional terminal blocks are compatible with
Acromag’s “white box” modules including
BusWorks 900 Series, InliPack 800 Series, and
isolated transmitters 600 Series.
Barrier Strip
Spring Clamp
Standard Cage Clamp
Performance Specifications
Barrier Strip Terminal Blocks
Wire Range: 12-26 AWG
Safety Ratings: UL, CSA, CE, TUV.
Current/Voltage Rating: 15A, 300V.
Pin Spacing: 5.08mm (0.2”).
Housing Material: PPO, UL 94 V-0, Black.
Contacts: Tin-Lead Plated Phosphor Bronze.
Screw: M3, Nickel Plated Steel.
Insulation Resistance:
≥
10
5
Megohms.
Dielectric Withstand: <3000V.
Spring Clamp Terminal Blocks
Wire Range: 12-28 AWG.
Safety Ratings: UL, CSA, CE, TUV.
Current/Voltage Rating: 15A, 300V.
Pin Spacing: 5.08mm (0.2”)
Housing Material: PPO, UL 94 V-0, Black.
Contacts: Tin-Lead Plated Phosphor Bronze.
Spring Clamp: Stainless Steel.
Insulation Resistance:
≥
10
5
Megohms.
Dielectric Withstand: <3000V.
Acromag Standard Cage Clamp Terminal Blocks
Wire Range: 12-24 AWG.
Current/Voltage Rating: 12A, 300V (UL).
Pin Spacing: 5.08mm (0.2”).
Housing Material: UL 94 V-0.
Terminal: Brass, nickel plated.
Wire Protector with Contact: Copper alloy tin plating.
Screw: M3, steel, nickel over copper plating.
Contact Resistance:
≤
10 milliohms per circuit.2015
-
16
Pric
e List for Alternative Control Services
v.
4秒報價 FMI W5G45A23T451,Nr.36349 離心通風機
page
24
2
Price List
The upfront charges applying to new Type 5 and 6 meter installations are provided in
Table
2
.
4
.
These charges will be billed to retailers and will apply to
all new meters
installed from 1 July 20.
5
Table
2
.
4
: Metering upfront charges
for new installations, 2015
-
16
Metering upfront charges
–
new installations
Fixed charge
(/meter)
Fixed charge
(/meter)
GST Exclusive
GST Inclusive
Upfront charge
-
Single phase
-
Primary
389.04
427.95
Upfront charge
-
Single phase
-
Primary plus
solar
38.01
4.61
Upfront charge
-
Dual element
-
Primary plus controlled load
4.52
479.07
Upfront charge
-
Dual element
-
Primary plus controlled load plus solar
43.48
47.73
Upfront charge
-
Polyphase
-
Primary
480.05
528.06
Upfront
charge
-
Polyphase
-
Primary plus solar
477.02
5.72
Upfront charge
-
Additional single phase meter for controlled load purposes
39.78
4.46
Upfront charge
-
Additional polyphase meter for controlled load purposes
487.79
5.57
Upfront charge
-
Additional single phase meter to accommodate additional tariffs
other than controlled load
40.28
44.41
Upfront charge
-
Additional polyphase meter to accommodate additional tariffs
other than controlled load
49.29
54.52
Upfront
charge
-
New single phase meter to accommodate solar installation
398.24
438.0
7
Upfront charge
-
New polyphase meter to accommodate solar installation
489.25
538.18
5
The imple
mentatio
n of upfront metering charges has been deferred until 1 August 2015
.
2015
-
16
Pric
e List for Alternative Control Services
v.
4
page
25
2
Price List
.3
Public L
i
ghting S
ervices
Public Lighting Services
prices
are
based on the type of light and the ownership basis
(
i.e. E
rgon
Energy
O
wned
&
O
perated (EO&O)
or
Gifted & Ergon
Energy
Operated
(
G&EO)
)
.
A listing of Ergon Energy’s
Public Lighting Services and their charges is provided in
Table
2
.
5
.
Additionally, Ergon Energy will charge an exit fee when public lighting assets are withdrawn before the end of their normal f
unctional life
.
6
These charge
s are provided in
Table
2
.
6
.
Table
2
.
5
:
Daily
Public Lighting Services
charges, 2015
-
16
Public Lighting Services
Fixed
charge
(/day/light)
Fixed charge
(/day/light)
GST Exclusive
GST Inclusive
EO&O
-
Major
.0252
.1277
EO&O
-
Minor
0.6108
0.6719
G&EO
-
Major
0.4140
0.4554
G&EO
-
Minor
0.2712
0.2983
Table
2
.
6
: Public Lighting Services exit fees
, 2015
-
16
Public Lighting Services
/light
/light
GST Exclusive
GST Inclusive
EO&O
-
Major
-
Exit Fee per light
1,4.91
1,55.30
EO&O
-
Minor
-
Exit Fee per light
85.45
939.89
G&EO
-
Major
-
Exit Fee per light
23.96
257.35
G&EO
-
Minor
-
Exit Fee per light
198.35
218.19KT 210 / max. 2048 TP
max. 12 VDC / 10 mA
KT 230 / max. 256 TP
max. 1000 VDC / 400 mA
NT 210 / max. 2048 TP
max. 12 VDC / 10 mA
NT 230 / max. 256 TP
max. 1000 VDC / 400 mAKT 410 / max. 16384 TP
max. 25 VDC / 25 mA
KT 630 / max. 1024 TP
max. 1500 VDC / 2 A
max. 1050 VAC / 5 mA
KT 638 / max. 512 TP
max. 1500 VDC / 2 A
KT 644 / max. 1024 TP
max. 2150 VDC / 1500 VAC
NT 410 / max. 16384 TP
max. 25 VDC / 25 mA
NT 600 / max. 5120 TP
max. 1500 VDC / 2 A
max. 1050 VAC / 5 mA
NT 600 TPI/FPI / max. 5120 TP
max. 1500 VDC / 2 A
max. 1050 VAC / 5 mA
NT 637 / max. 512 TP
max. 1500 VDC / 2 A
max. 1050 VAC / 5 mANT 700 / max. 32768 TP
max. 6000 VDC / 2 A
max. 5000 VAC / 30 mA
NT 830 - HV Distributed Test
max. 131072 TP
max. 1500 VDC / 2 A
max. 1050 VAC / 5 mA
NT 850 - HV Distributed Test
max. 131072 TP
max. 6000 VDC / 2 A
max. 5000 VAC / 30 mAKT 235 - Multibox / max. 512 TP
max. 1000 VDC / 400 mA
NT 235 - Multibox / max. 512 TP
max. 1000 VDC / 400 mA
NT 730 LTM / max. 256 TP
max. 1000 VDC / 2 ANT 910 / NT 920 - Direct Test
max. 131072 TP
max. 250 VDC / 100 mAOLT 880 Test tables
new: TD0800 - functional - economic - compact
Test Consoles PT 60 , PT 40
Adapter console AP01
Adapter console AP02-3 for multifunctional adapter boards adaptronic-Hand-Adapter.pdf
adaptronic-Rigging-Harness .pdf
ECU Tuning Software, Help Doco, Firmware
Modular and Select ECUs
Eugene – Adaptronic Engine Management Software (Latest beta release)
Modular ECU basemap
Quick Download for Select and e420c ECUs (Select includes 440, e420d and plug-ins)
ECU Tuning Software, Help Doco, Firmware
Select and e420c
Latest Download (version .000)
Note: Please check the revision history below
Quick Download for e1280s ECU
ECU Tuning Software, Help Doco, Default Configuration, Firmware/Package
e1280s Latest Download (version .000)
Quick Download for Installation and Startup guides
A. Wire-in ECUs
ECU Pinout document
(.pdf)
Wiring diagram
(.pdf)
Basemap
(.ecu)
e420d Universal Select ECU 420_Pinout 420_Wiring Uni420_BaseMap
e440d Universal Select ECU 440_Pinout 440_Wiring Uni440_BaseMap
e1280s Fully Configurable ECU e1280s_Pinout e1280s_Wiring e1280sDefaultConfig
B. Plugin ECUs
Maker Model Series Pinout/Setup Guide (.pdf) Basemap (.ecu)
Dodge Neon SRT-4 SRT4 SRT4_Sel_Basemap
Mazda MX5 / Miata NA8C MX5NA8_Sel_pinout and setup guide MX5NA8_Sel_BaseMap
Mazda MX5 / Miata NB8A MX5NBA_Sel_pinout and setup guide MX5NBA_Sel_BaseMap
Mazda MX5 / Miata NB8B MX5NBB_Sel_pinout and setup guide MX5NBB_Sel_Basemap
Mazda MX5 / Miata NB8C-SE MX5NBB_Sel_pinout and setup guide MX5NBBSE_Sel_Basemap
Mazda MX5 / Miata NB8C-SP MX5NBB_Sel_pinout and setup guide MX5NBBSP_Sel_Basemap
Mazda RX7 Series 4 RX7_S4_Sel_pinout and setup guide RX7_S4_Sel_Basemap
Mazda RX7 Series 5 RX7_S5_Sel_pinout and setup guide RX7_S5_Sel_Basemap
Mazda RX7 Series 6 RX7_S6_Sel_pinout and setup guide RX7_S6_Sel_Basemap
Mazda RX7 Series 8 RX7_S8_Sel_pinout and setup guide RX7_S8_Sel_pinout
Mazda RX8 Series 1 RX8_Sel_pinout and setup guide RX8_Sel_Basemap
Mitsubishi Lancer EVO 4-8 EVO4-8 Evo_BaseMap
Nissan 300ZX Z32 R33_Sel_15_pinout and setup guide Z32_Sel_BaseMap
Nissan Silvia S13 180SX
(Redtop)
S13_Sel_pinout and setup guide S13_Sel_BaseMap
Nissan Silvia S13 180SX / 200SX
(Blacktop)
S15_Sel_pinout and setup guide S13x_Sel_BaseMap
Nissan Silvia S13 240SX 240SX_Sel_pinout and setup guide 240SX_GTiR_Sel_Basemap
Nissan Silvia S14 200SX/240SX S14_Sel_pinout and setup guide S14_Sel_BaseMap
Nissan Silvia S14a 200SX S15_Sel_pinout and setup guide S14a_Sel_BaseMap
Nissan Silvia S15 200SX S15_Sel_pinout and setup guide S15_Sel_BaseMap
Nissan Skyline R32 (GTST) R33_Sel_15_pinout and setup guide R32_Sel_15_BaseMap
Nissan Skyline R33 (GTST) R33_Sel_15_pinout and setup guide R33_Sel_15_BaseMap
Nissan Skyline R32 / R33/ R34 Evaluation units and analyzers
- Multitronik 592
- LON
?
Center 2000
- GW 399
- MWS 906
- MWS 906 CP
- MWS 903
- MWS 897
- ITR 504
- Biogas 401
- Biogas 905
- KM 2000 CnHm
- RG 399
est.1900
Multitronik 592
a
D
os
g
mbH
i
nstrumentation and Control
P.
o
. Box 500 444 · 52088
a
achen ·
frg
Trierer
s
trasse 23 - 25 · 52078
a
achen ·
frg
f
ax: +
i
Measure
M
en
T
, Con
T
rol an
D
Warning
u
ni
T
for
s
ensors
i
nstrumentation and Control
est. 1900
standard
compact
Multitronik 592
Measure
M
en
T
, Con
T
rol an
D
Warning
u
ni
T
for
s
ensors
ADOS GmbH
Instrumentation
and Control
ADOS Multitronik 592 is a modular-constructed measure
-
ment, control and warning unit, designed for universal
use with gas sensors.
Various types of sensors can be connected to the system
by means of a 4
–
20 mA current interface or the LON
?
field-bus.
ADOS Multitronik 592 in conjunction with the ADOS 592
TOX CO LON
?
gas-test sensor, conforms to the require
-
ments of the German VDI 2053 standard.
The microcontroller-aided unit allows installation of an
all-electronic version without pneumatic components as
well as the assembly of a version with gas intake.
In the all-electronic version, each measuring point is fit
-
ted with a local gas sensor, with the signals being trans
-
ferred to the unit by way of a current interface.
Specific application versions, using 19"-techniques, are
realised by inserting standard format plug-in Euro-cards
into a Bus system and the use of the modules required
for a defined application.
a
pplication
■
In garages and tunnels for measurement, control and
warning, according to the German VDI 2053 standard,
with ADOS TOX 592 CO LON
?
carbon monoxide
sensors
■
For monitoring the air at working places, to control
the maximum level of concentration and for protection
against explosion
■
In shelters for monitoring the external and internal air
■
For measuring the concentration of exhaust and
waste gases at motor and brake test benches
■
Monitoring liquid gas reservoirs
■
Control of cold storage houses
■
Control of fruit storage cells
f
ields of
a
pplication
est. 1900
Multitronik 592
Measure
M
en
T
, Con
T
rol an
D
Warning
u
ni
T
for
s
ensors
ADOS GmbH
Instrumentation
and Control
All information significant to operation is displayed in
clear text on a 4-line, 16-digit display.This information
includes the gas actual value, gas half-hourly average
value, monitoring period, measuring point, sequence
timing, alarm and faults (or errors).
The alarms and centralised malfunctions are all
indicated by LED ?s.
A total 6 keys are used to operate the equipment.
Four keys, together with menu-assistence, are used for
defining the number of measuring points, the monitor
-
ing period and other parameters without any previous
knowledge of programming. An electronic check of the
units including the display of a single selected measur
-
ing point, is initiated by pressing a key. The siren after
an alarm, can be cancelled either at the unit or as an
option, externally.
Digital switching outputs can be used for any ventilation
and alarm control units; digital inputs are also available
for external signals.
For data communication RS 232 or RS 485 as well as cur
-
rent outputs 0 (4)–20 mA or voltage outputs 0–10 V and
the LON
?
field-bus are provided as standards interfaces.
ADOS Multitronik 592 is almost independent of mains
supply networks. A line filter is provided as a standard.
A charging unit for 24 V battery supply is integrated.
The apparatus can be equipped with or without UPS
(uninterruptable power system), according to the
German VDI 2053 recommendations.
The unit is delivered as standard, in a three-section
sheet-steel housing with transparent lockable door,
according to IP 54 standards.
Control and power sections for the ventilator drive are
mounted on an installation panel.
Design and
o
perational Characteristics
The complete
a
D
os
Multitronik 592 gas measurement
system consists of the following system components:
■
ADOS 592 gas sensors in a housing with amplifier and
4
–
20 mA current interface
■
Input & output cards and modules for standardized
input and output signals
■
Microcontroller-aided evaluation unit in 19"-system
with application specific, standard plug-in Euro cards
■
Measuring units with integrated gas sensors for gas
intake system with measuring point selection switch
and filter, optionally available with automatic
calibration unit
■
Portable test unit, including battery with integrated
charging unit incorporating discharge protection
■
Power and control units for ventilators
■
The housing
e
quipment Description
est. 1900
www.neck-heyn.de ? 03_2013
Multitronik 592
Dimensions (HxD):
600 x 345 x 500 mm
Weight:
approx. 20 kg
Protection class
acc. to DIN 40050:
IP 54
Version “standard”
Dimensions (HxD):
355 x 260 x 240 mm
Weight:
approx. 5 kg
Protection class
acc. to DIN 40050:
IP 55
Version “compact”
ADOS GmbH
Instrumentation
and Control
Sensor inputs:
4-20 mA current interface for
connecting sensors using
two- or three-wire techniques
LON
?
four-wire techniques
galvanically isolated,
data transmission 78 kbps
Digital inputs:
Opto-isolated inputs,
with galvanically isolated
power supply
Digital outputs:
Floating control outputs
max. 230 V 4A 900 VA
Warning outputs
max. 230 V 6A 1400 VA
Standard output
signals:
Serial interfaces RS 232 or RS
485 Analog Output 0
–
10 V or
0 (4)
–
20 mA option - galvanically
isolated LON
?
fieldbus,
galvanically isolated,
data transmission 78 kbps
Battery operating time:
>
10
h with “mains fault” display,
battery discharge protection
> 1
h optionally, maintaining all
Multitronik 592 functions
Battery charging time:
15
–
16 h,
permanent charging system
Power supply:
24 V
–
230 V, 130 VA , DC or AC
Test certificate:
To German standards,
according to VDI 2053 in
conjunction with ADOS 592 CO
test numbers:
09-02-0120
09-95-0128
432-987615
Technical Data
Measure
M
en
T
, Con
T
rol an
D
Warning
u
ni
T
for
s
ensors
est. 1900
LON
?
CENTER 2000
Instrumentation and Control
est.1900
ADOS GmbH
Instrumentation and Control
P.O. Box 500 444 · 52088 Aachen · FRG
Trierer Strasse 23-25 · 52078 Aachen · FRG
+
i
Me
AS
u
R
e
M
en
T
, C
O
n
TRO
l
A
n
D
W
AR
n
I
n
G
u
n
IT
FOR
Sen
SORS
www.neck-heyn.de · 11_2010
LON
?
CENTER 2000
ADOS GmbH
Instrumentation
and Control
est.1900
Details as for control unit
Sensors:
LON
?
4-wire techniques,
galvanically isolated,
data transfer 78 kB/s
24V sensor supply
Ranges:
adjustable via software
Digital inputs:
Opto-isolated input with isolated
voltage supply (siren cancel,
ventilator fault)
Digital outputs:
Floating Control outputs
max. 230 V 2A
Warning outputs
max. 230 V 4A
Battery operating time:
>10 hours with mains failure
display
>1 hour optional, retaining all
functions
Standard output
signals:
Serial interface RS 232
Analog output, 4-20 mA
Ambient temperature:
-10 °C to +40 °C
Dimensions (HxD):
240 x 160 x 90 mm
Mains connection:
230 V~ / 50 Hz; 115 V~ / 60 Hz
or optionally 24 V= 50 VA
Test certificate:
TüV acceptance test according
to VDI 2053, together with ADOS
592 TOX CO LON
?
Approval symbol:
931-981289
Gas
Formula
Acetylen
C
2
H
2
Ether
C
4
H
10
O
Alcohole
e.g. C
2
H
6
O
Ammonia
NH
3
Petroleum spirit
Butane
C
4
H
10
ADOS LON
?
Center 2000 is a test, control and warning unit
for the techniques of gas-sensorics. It continuously moni
-
tors the surrounding air and provides an early warning
of dangerous, explosive and non-combustible gases and
vapours.
Various types of sensor can be connected to the system
via the LON
?
field-bus.
The ADOS LON
?
Center 2000, together with the ADOS 592
TOX CO LON
?
gas test-sensor, conforms to the German
guideline VDI 2053.
Signal horn, warning light, warning banner, test meters,
plotter, LON
?
relay module, LON
?
repeater, stand-by
power supply UPS 2000 - 24V.
Additional accessories will be offered, according to the
system required.
■
Monitoring of heating systems
■
Garages and tunnels
■
Liquid gas storage rooms
■
Laboratories
■
Cold storage houses
■
Plastic processing plants
■
Chemical industries
■
Paint manufacturing plants
■
Concentration measurement of O
2
■
and many more
■
Choice of up to 40 different test sensors
■
One monitoring area (optionally, up to 5 areas)
■
Menu-assisted operation via 4 keys
■
5 alarm levels, independently adjustable from 5 to
* of the test range selected
■
Ready, Fault and Gas warning indicators
■
6 floating alarm outputs for driving external warning
and control equipment
■
Floating contact connections for fault and mains
failure
■
Serial interface output, RS 232
■
LON
?
-Interface
■
4 – 20 mA current interface
■
Hammer-proof thermoplastic housing
■
High operational reliability
■
Low current consumption
■
Easy installation
■
UPS unit available
Technical Data
Accessories
Fields of Application
Features
Measurable gases
Application
Chloroform
CHCl
3
Hydrogen chloride
HCI
Helium
He
Carbon dioxid
CO
2
Carbon monoxid
CO
Methane (natural gas)
CH
4
Neon
Ne
Propane
C
3
H
8
Oxygen
O
2
Carbon tetrachloride
CCl
4
Toluene
C
7
H
8
Hydrogen
H
2
Xylene
C
8
H
10
Me
AS
O
n
TRO
l
A
n
D
W
AR
n
I
n
G
u
n
IT
FOR
Sen
SORS
Instrumentation and Control
est.1900
ADOS GmbH
Instrumentation and Control
P.O. Box 500 444 · 52088 Aachen · FRG
Trierer Strasse 23-25 · 52078 Aachen · FRG
+
i
MULTI-CHANNEL GAS WARNING SYSTEM
GW 399
Compact
Standard
www.neck-heyn.de ? 11_2010
Helium
He
Hydrogen
H
2
Hydrogen chloride
HCl
Methane
CH
4
Neon
Ne
Oxygen
O
2
Petrol
Propane
C
3
H
8
Toluene
C
7
H
8
Xylene
C
8
H
10
Gas
Formula
Acetylene
C
2
H
2
Alcohol
e.g. C
2
H
6
O
Ammonia
NH
3
Butane
C
4
H
10
Carbon dioxyde
CO
2
Carbon monoxide
CO
Carbon tetrachloride
CCI
4
Chloroform
CHCI
3
Ether
C
4
H
10
O
The multi-channel gas warning system GW 399
conti
nunosly monitors the ambient air and provides an
early warning of
hazardous, explosive and non-com
-
bustible gases and vapours.
Application
■
Monitoring of heating systems
■
Garages and tunnels
■
Liquid gas storage rooms
■
Laboratories
■
Cold-storage houses
■
Plastic processing plants
■
Chemical industries
■
Paint manufacturing plants
■
Concentration measurement of O
2
■
and many more
Fields of Application
■
Use of various types of measurement sensor
■
Direct warning status recognition, via different colors
of the LC-Display background illumination
■
Menu-aided operation, via 2 keys
■
Three alarm thresholds individually adjustable
from 5–100 % of the test range
■
Three floating alarm outputs for driving additional
warning and control systems
■
Floating relay contacts
■
Serial output RS 232 or RS 485
■
LON
?
-Interface
■
4–20 mA current output
■
Different housings are available e.g. 19" rack,
panel mounting, wall-mounted housing
■
Up to 10 units per rack
■
1 control unit configurable as master, for supervision
of central alarms and communication control systems
■
High degree of reliability
■
Low current consumption
■
Possibility of uninteruptible power supply
Features
Signal horn, Warning light, Warning banner, Ventilation
control, Test meters, Plotter.
Additional accessories are available, depending on the
system
ordered.
ADOS GmbH
Instrumentation
and Control
GW 399
MULTI-CHANNEL GAS WARNING SYSTEM
Accessories
Measurable gases
Details as for control unit
Sensors:
Semiconductor sensor
Heat reaction sensor
Thermal conductivity sensor
Chemical sensor
Infrared sensor
Sensors input:
1 two-wire sensor
(e.g. TOX 592) or
1 three-wire sensor
(e.g. GTR 196)
Sensor supply:
20 V DC / 200 mA
Ranges:
Adaptable by software
Accuracy:
< 2 %, f.s.d.
Ambient temperature:
-10 °C to +40 °C
Temperature effects:
< 2 % for a ±20 °C change
Installation:
Panel-mounting or
wall-mounting
Output signals:
Current output 4–20 mA
RS 232 or RS 485 interface
LON
?
-Interface
3 Alarm relays,
1 Fault relay
Relay rating:
230 V, 450 VA
other voltages on request
Voltage supply:
230 V 50 Hz
Options:
115 V 60 Hz; 24 V DC; 12 V DC
Power consumption:
8 VA
Technical Data
est.1900
- Tunnel Application -
EMC and Wat
E
r Prot
EC
tion Housing V2
a
for u
P
to 4
ados
gas trans
M
itt
E
rs
ADOS GmbH
Instrumentation and Control
P.O. Box 500 444 · 52088 Aachen · FRG
Trierer Strasse 23 - 25 · 52078 Aachen · FRG
+49 (0)
2 41 / 97 69 - 0
+49 (0)
2 41 / 97 69 - 16
i
est. 1900
www.neck-heyn.de · 02_2013
EMC and Wat
E
r Prot
EC
tion Housing V2
a
for u
P
to 4
ados
gas trans
M
itt
E
rs
- Tunnel Application -
Compatible ADOS
gas transmitters:
ADOS 592 TOX and
LCTR 903 (TGS, VQ, IR)
including polyamide-
adapter and EMC
interference filter CSEF
Number of ADOS
gas transmitters
:
up to 2 units
Housing material:
V2A stainless steel
Protection degree:
corresponds to IP 65
Dimensions (W
x
H
x
D):
260 x 240 x 160 mm
Weight (including gas
transmitters):
approx. 3,6 kg
Compatible ADOS
gas transmitters:
ADOS 592 TOX and
LCTR 903 (TGS, VQ, IR)
including polyamide-
adapter and EMC
interference filter CSEF
Number of ADOS
gas transmitters
:
up to 4 units
Housing material:
V2A stainless steel
Protection degree:
corresponds to IP 65
Dimensions (W
x
H
x
D):
560 x 320 x 200 mm
Weight (including gas
transmitters):
approx. 10,4 kg
f
ields of
a
pplication
Tunnel installations are characterized by a high degree of EMC disturbance
(by tunnel radio) and by the occurence of water (during tunnel cleaning). The
EMC and Water Protection Housing V2A provides an enhanced protection in
order to increase the EMC resistance as well as a reliable protection again
water intrusion into the gas transmitters. All gas transmitters, that are usually
installed to monitor tunnel atmospheres (CO, NO, NO
2
, LEL), can be used along
with the EMC and Water Protection Housing V2A.
ADOS GmbH
Instrumentation
and Control
est. 1900
Version
a
– up to 2 gas transmitters
Version B – up to 4 gas transmitters
ITR 498
Instrumentation and Control
est. 1900
ADOS GmbH
Instrumentation and Control
P.O. Box 500 444 · 52088 Aachen · FRG
Trierer Strasse 23 - 25 · 52078 Aachen · FRG
+
i
In
FRAR
e
D
GAS A
n
ALYS
IS
S
YST
em
www.neck-heyn.de · 09_2013
ITR 498
Test principle:
Non-dispersive infrared analysis
Range:
0
–
5.000 ppm to 0
–
100 Vol.% CO
2
hand-held tester:
0
–
2 Vol.
% to 0
–
100 Vol.
% CO
2
Response
time (t
90
):
<
20 sec
Linearity error:
<
2
%
Accuracy:
<
±3
% of upper range value
Overall
accuracy:
<
3
% of upper range value
Long-term drift:
<
0,5
% / month
Ambient
temperature:
Test unit: -20 °C to +45 °C
(optional: -30 °C to +45 °C)
Transmitter: -20 °C to +45 °C
Hand-held tester: -20 °C to +45 °C
Protection class:
IP 54
Trans-
mitter
Test
unit
Hand-held
tester
Voltage supply:
12 – 25 V
DC
230 V /115
V
AC
12
V
Battery
Power
consumption:
2 VA
9 VA
9 VA
(charge)
Battery life
(on charge):
>
8
h
Outputs:
RS
232 4
–
20 mA
Floating
contacts
Optional extra
measurements:
O
2
Dimensions
(HxD) mm:
120 x 120
x 90
120 x 120
x 90
120 x 200
x 60
Weight:Product Series Selection Guide
Remote I/O
Inputs
Outputs
Network Protocol
Ethernet I/O Modules
BusWorks XT Series
Up to 16 channels/module;
analog (current, voltage), discrete
Analog (current, voltage), discrete
Modbus TCP/IP, Ethernet/IP, Profinet,
i2o peer-to-peer
BusWorks 900EN Series
Up to 16 channels/module; analog (TC, RTD, current,
voltage), 3B/5B/7B/8B cable interface, discrete
Analog (current, voltage), discrete
Modbus TCP/IP, Ethernet/IP,
i2o peer-to-peer
Etherstax ES2000 Series
Up to 96 channels/module;
analog (current, voltage), discrete
Analog (current, voltage), discrete Modbus TCP/IP, UDP/IP, i2o peer-to-peer
RS-485 I/O Modules
BusWorks 900MB Series
Up to 12 channels/module;
analog (TC, RTD, current, voltage), discrete
Analog (current, voltage), discrete Modbus-RTU
BusWorks 900PB
Up to 12 channels/module;
analog (TC, RTD, current, voltage), discrete
Analog (current, voltage), discrete Profibus-DP
877-214-6267 or 248-295-0880
■
s
■
■
30765 S Wixom Rd, Wixom, MI 48393 USA
8400-674 ? Acromag, Inc. 2012. Data subject to change without notice. Printed in USA 9/2012
Monitoring and Control Solutions
NEW!
NEW!
NEW!
NEW!
NEW!
Signal Conditioners Inputs
Outputs
Power
Signal Isolators
TT230 Series (TT236) Single-channel; 4-20mA
4-20mA universal sink/source 2/3-wire; 12-32V DC (output loop power)
TT330 Series (TT336) Single-channel; 4-20mA
4-20mA source
4-wire; 12-32V DC
630T Series (631T, 632T) Single/dual-channel; 4-20mA
4-20mA source
4-wire; 15-36V, 125V DC; 90-250V AC
650T Series (651T, 652T) Single/dual-channel; 4-20mA
4-20mA sink
2-wire; 12-36V DC (output loop power)
670T Series
Single/dual/quad-channel; 4-20mA
4-20mA source
2-wire; input loop power
Signal Splitters
630T Series (633T)
Single input; 4-20mA
Dual output; 4-20mA source
4-wire; 15-36V, 125V DC; 90-250V AC
650T Series (653T)
Single input; 4-20mA
Dual output; 4-20mA sink
2-wire; 12-36V DC (output loop power)
Signal Transmitters and Converters
ST130 Series
Single-channel; thermocouple, RTD, resistance, millivolt 4-20mA sink
2-wire; 9-32V DC (output loop power)
TT230 Series
Single-channel; current, voltage, thermocouple, RTD,
thermistor, resistance, potentiometer, frequency
4-20mA universal sink/source 2/3-wire; 12-32V DC (output loop power)
TT330 Series
Single-channel; current, voltage, thermocouple, RTD,
thermistor, resistance, potentiometer, frequency
Scalable ±10V, 0-10V,
±20mA, 0-20mA source
4-wire; 12-32V DC
1500 Series (151T, 155H) Single input; thermocouple, RTD, resistance, mV, current 4-20mA sink, HART; LCD display 2-wire; 12-42V DC (output loop power)
610T Series
Single/dual-channel; current, voltage
Scalable 0-10V, 0-20mA source 4-wire; 10-36V DC
650T Series (654T)
Dual-channel; current, voltage
4-20mA sink
2-wire; 12-50V DC (output loop power)
650T Series (655T, 656T) Single/dual-channel; thermocouple, millivolt
4-20mA sink
2-wire; 12-50V DC (output loop power)
650T Series (657T, 658T) Single/dual-channel; RTD, resistance
4-20mA sink
2-wire; 12-50V DC (output loop power)
800T InliPack Series
Single/dual-channel; current, voltage, thermocouple, RTD,
resistance, frequency/pulse, strain gage (bridge), load cell
Scalable 0-10V, 0-20mA source,
alarm relay
4-wire; 10-36V DC
Limit Alarms
800A InliPack Series
Single/dual-channel; current, voltage, thermocouple, RTD,
resistance
Single DPDT or dual SPDT 5A relays 4-wire; 10-36V DC
260A / 361A / 461A
Flat Pack Series
Single-channel; current, voltage Single/dual SPDT 2A or 5A alarm relays
2/3/4-wire; input loop-powered (4-20mA);
10-36V DC; 115/230V AC
Computation
InliPack (892M, 894M) Dual/quad input; current, voltage
Single output; 0-20mA source, 0-10V 4-wire; 10-36V DC
InliPack (895M, 896M) Single/dual-channel; current, voltage
Frequency, pulse, pwm, alarm relay 4-wire; 10-36V DC
NEW!
248-295-0880
■
248-624-9234
■
s
■
■
30765 Wixom Rd, Wixom, MI 48393 USA
Ethernet I/O: BusWorks
?
XT Series
Bulletin #8400-654c
Description
The XT1110 interfaces discrete I/O signals
between measurement and control devices over
Ethernet. Channels are individually configurable
for input or low-side switched output operation.
Rugged construction, high density design, and
easy USB-to-PC/Windows setup combine for a
very effective I/O solution. These units are ideal
for remote monitoring, distributed control, or
SCADA applications.
Input/Output Ranges
Input: 0-32V DC, TTL thresholds
Output: 0-32V DC, open-drain, up to 250mA
Ethernet Communication
Modbus TCP/IP, Ethernet/IP, Profinet,
i2o
?
peer-to-peer, 10/100Base-T(X)
PriorityChannel? device determinism
Power Requirement
12 to 32V DC (2.5W)
Key Features & Benefits
■
16 solid-state discrete I/O channels
(any mix of inputs or outputs)
■
Built-in 10K ohm pull-up resistors for
2/3-wire sensors (contacts, proximity, TTL)
■
Configurable normal/reverse input logic
■
Outputs include built-in read-back capability
■
Easy setup with Windows software via USB
■
.
Watchdog timer control of failsafe outputs
■
.
Continuously changing “heart-beat” register
validates module operation
■
High-Density 22.5mm wide package with
pluggable, front-facing terminals
■
Dual Ethernet 10/100 ports (auto-negotiation)
reduce switch port requirements
■
1500V AC isolation (between I/O, power, and
network ports) and surge/transient protection
■
Supports bussed/rail and redundant power
■
-40°C to +70°C wide temperature operation
■
Withstands 25g shock and 4g vibration
■
CE and UL/cUL Class 1 Div 2 Zone 2 approvals
16 discrete tandem input/output channels
◆
Modbus TCP/IP, Ethernet/IP, Profinet, or i2o communication
XT1110
Ethernet Discrete I/O Modules (sinking outputs)
99.0
(3.90)
114.5
(4.51)
22.5
(0.89)
DIMENSIONS ARE IN
MILLIMETERS (INCHES
)
+3.3V
100K
10
K
DIN
DOUT
DI/O
RTN
EX
C
XT111x SIMPLIFIED I/O CHANNE
L
TTL
48WV
R
OFF (0
)
ON (1
)
EXAMPLE INPUT CONNECTIONS
EXAMPLE OUTPUT CONNECTIONS
NORMALLY
OPEN DR
Y
CONTAC
T
DI/O
RTN
EX
C
DI/O
RTN
EX
C
DI/O
RTN
EX
C
N.O.
+
12-32V DC
12-32V DC
12-32V DC
N.C.
+
NORMALLY
CLOSED DR
Y
CONTAC
T
+
LA
MP
USB
Configured
BusWorks XT software (download free from ) allows you to configure I/O modules offline with
USB, save the file, and download settings into units later, at your convenience.
248-295-0880
■
248-624-9234
■
s
■
■
30765 Wixom Rd, Wixom, MI 48393 USA
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 8/2013
Ethernet I/O: BusWorks
?
XT Series
XT1110
Ethernet Discrete I/O Modules (sinking outputs)
Performance Specifications
■
USB Interface
USB Connector
Type: USB Mini-B type socket, 5-pin.
Data rate: 12Mbps. USB v1.1 and 2.0 compatible.
Maximum cable length: 5.0 meters.
USB Transient Protection
Transient voltage suppression on power and data lines.
Driver
Not required. Uses Windows HID drivers.
■
Input
Input Type
16 active-low, buffered inputs, with a common
connection. Inputs are tied in tandem to output drains
for optional loopback monitoring of output state.
Input Signal Voltage Range
0 to 32V DC.
Input Current
280μA, typical at 32V DC.
Input Signal Threshold
1.7V typical with100mV of hysteresis.
Input Resistance
100K ohms, typical.
Input Response Time
10ms, nominal.
■
Output
Output Type
16 open-drain, smart, n-channel mosfet switches
with a common source connection. Provides low-side
(sinking) switching between the load and return.
Output Voltage
0 to 32V DC.
Output “ON” Resistance
0.8 ohms typical, 1.6 ohms maximum.
Output “ON” Current Range
0 to 250mA DC, continuous (up to 4A total for all
16 channels combined). See Operating Temperature
specification for effect of channels at full load. See
manual for detailed effects of operating temperature.
Output Response Time
10ms, nominal.
■
Ethernet Communication
Protocols
Modbus TCP/IP, i2o peer-to-peer, Ethernet/IP, or
Profinet depending on model number.
Ethernet Communication Controller
Innovasic RapID? Platform with PriorityChannel? for
determinism at the device regardless of network load.
Modbus TCP/IP (slave)
Port 502 reserved. Supports up to 10 sockets.
i2o Peer-to-Peer (master/slave)
Can map 4-channel input groups to output groups at
two destination IP addresses. Timed or change-of-state
updates. Supports GPRS/GSM systems.
Ethernet/IP (adapter)
Supports 16 connections. EDS file on website.
Profinet (server)
Supports 1 connection. GSDML file on website.
Connectors
Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.
Wiring
Auto-crossover for MDI or MDI-X.
IP Address
User-configurable. 128.1.1.100 default static IP address.
Data Rate
Auto-negotiated, 10Mbps or 100Mbps.
Compliance
IEEE 802.3, 802.3u, 802.3x.
■
Environmental
Operating temperature
-40 to 70°C (-40 to 158°F). Max temperature derates
-0.625°C per output channel at full load (250mA).
Storage temperature
-40 to 85°C (-40 to 185°F).
Relative humidity
5 to 95% non-condensing.
Power Requirement
12 to 32V DC (102mA maximum @ 24V).
Isolation
4-way isolation between I/O channels, network
(each port), and power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.
Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals
CE compliant. UL/cUL Class I; Div. 2 Zone 2.
■
Physical
General
General purpose plastic enclosure for mounting on
35mm “T-type” DIN rail.
Case Material
Self-extinguishing polyamide, UL94 V-0 rated, color
light gray. General purpose NEMA Type 1 enclosure.
Circuit Board
Military grade fire-retardant epoxy glass (IPC-4101/98).
I/O Connectors
Removable plug-in type terminal blocks rated for
12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions
Width = 22.5mm (0.9 inches), Length = 114.5mm
(4.51 inches), Depth = 99.0mm (3.90 inches).
Shipping Weight
0.5 pounds (0.22 Kg) packed.
Ordering Information
◆
Models
XT1111-000
Digital I/O module, Modbus/TCP and i2o protocol.
XT1112-000
Digital I/O module, Ethernet/IP protocol.
XT1113-000
Digital I/O module, Profinet protocol.
◆
Software
XT-SIP
(
recommend one kit per customer
)
Software Interface Package. Includes software
(XT-CONFIG), isolator (USB-ISOLATOR), two USB cables
(4001-112, 4001-113), Ethernet cable (5035-360).
◆
Accessories
XTA-120V-6
XTA-240V-3
6-channel 120V AC/DC or 3-channel 240V AC/DC
discrete input module with 5V DC logic outputs.
Interfaces with sinking/sourcing DC Inputs.
XTA-MRNO-6
6-ch mechanical relay output module, Form A, SPST
normally open 5A relays (5/12/24V DC logic input).
XTBUS-KIT
DIN rail bus power/excitation connector kit. Includes
one DIN rail bus connector (1005-070), one left-side
female connector terminal block (1005-220) and one
right side male connector terminal block (1005-221).
USB-ISOLATOR
USB-to-USB isolator, includes USB cable (4001-112).
IMPORTANT: To prevent damage or errors from
grounded PCs and surges, Acromag strongly
recommends use of the USB-ISOLATOR when
configuring an XT1000 I/O module.
248-295-0880
■
248-624-9234
■
s
■
■
30765 Wixom Rd, Wixom, MI 48393 USA
Ethernet I/O: BusWorks
?
XT Series
Bulletin #8400-655c
Description
The XT1120 interfaces discrete I/O signals
between measurement and control devices over
Ethernet. Channels are individually configurable
for input or high-side switched output operation.
Rugged construction, high density design, and
easy USB-to-PC/Windows setup combine for a
very effective I/O solution. These units are ideal
for remote monitoring, distributed control, or
SCADA applications.
Input/Output Ranges
Input: 0-32V DC, TTL thresholds
Output: 0-32V DC, open-drain, up to 300mA
Ethernet Communication
Modbus TCP/IP, Ethernet/IP, Profinet,
i2o
?
peer-to-peer, 10/100Base-T(X)
PriorityChannel? device determinism
Power Requirement
12 to 32V DC (2.5W)
Key Features & Benefits
■
16 solid-state discrete I/O channels
(any mix of inputs or outputs)
■
Built-in 10K ohm pull-up resistors for
2/3-wire sensors (contacts, proximity, TTL)
■
Configurable normal/reverse input logic
■
Open-drain outputs switch up to 300mA each
and include built-in read-back capability
■
Easy setup with Windows software via USB
■
.
Watchdog timer control of failsafe outputs
■
.
Continuously changing “heart-beat” register
validates module operation
■
High-Density 22.5mm wide package with
pluggable, front-facing terminals
■
Dual Ethernet 10/100 ports (auto-negotiation)
reduce switch port requirements
■
1500V AC isolation (between I/O, power, and
network ports) and surge/transient protection
■
Supports bussed/rail and redundant power
■
-40°C to +70°C wide temperature operation
■
Withstands 25g shock and 4g vibration
■
CE and UL/cUL Class 1 Div 2 Zone 2 approvals
16 discrete tandem input/output channels
◆
Modbus TCP/IP, Ethernet/IP or Profinet communication
XT1120
Ethernet Discrete I/O Modules (sourcing outputs)
99.0
(3.90)
114.5
(4.51)
22.5
(0.89)
DIMENSIONS ARE IN
MILLIMETERS (INCHES
)
EXAMPLE INPUT CONNECTIONS
EXAMPLE OUTPUT CONNECTIONS
LOGIC (TTL)
LAMP CONTROL
VOLTAGE ON/OFF
EX
C
+3.3V
100K
10
K
DIN
DOUT
XT112x
SIMPLIFIED
I/O CHANNEL
TTL
48WV
R
EXC+
OFF (0
)
RTN
DI/O
48WV
ON (1
)
OFF (0
)
pd
PULL-DO
WN
TTL
Rlim
V<0.8
V
V>2.0
V
LOW
HI
GH
*OPTIONAL
V
DI/O
RTN
DI/O
RTN
2-32V DC
N.C.
+
OFF (0
)
ON (1
)
ACTIVE-LOW
OUTPUT
OUTPUT SINK
S
LOAD CURREN
T
LAMP
+
6-32V DC
DI/O
EXC+
RTN
USB
Configured
BusWorks XT software (download free from ) allows you to configure transmitters offline with
USB, save the file, and download settings into units later, at your convenience.
248-295-0880
■
248-624-9234
■
s
■
■
30765 Wixom Rd, Wixom, MI 48393 USA
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 8/2013
Ethernet I/O: BusWorks
?
XT Series
XT1120
Ethernet Discrete I/O Modules (sourcing outputs)
Performance Specifications
■
USB Interface
USB Connector
Type: USB Mini-B type socket, 5-pin.
Data rate: 12Mbps. USB v1.1 and 2.0 compatible.
Maximum cable length: 5.0 meters.
USB Transient Protection
Transient voltage suppression on power and data lines.
Driver
Not required. Uses Windows HID drivers.
■
Input
Input Type
16 active-high, buffered inputs, with a common
connection. Inputs are tied in tandem to output drains
for optional loopback monitoring of output state.
Input Signal Voltage Range
0 to 32V DC.
Input Current
280μA, typical at 32V DC.
Input Signal Threshold
1.7V typical with100mV of hysteresis.
Input Resistance
100K ohms, typical.
Input Response Time
10ms, nominal.
■
Output
Output Type
16 open-source, smart, p-channel mosfet switches
with a common drain connection. Provides high-side
(sourcing) switching between excitation and load.
Output Voltage
0 to 32V DC.
Output “ON” Resistance
0.8 ohms typical, 1.6 ohms maximum.
Output “ON” Current Range
0 to 300mA DC, continuous (up to 4.8A total for all
16 channels combined). See Operating Temperature
specification for effect of channels at full load. See
manual for detailed effects of operating temperature.
Output Response Time
10ms, nominal.
■
Ethernet Communication
Protocols
Modbus TCP/IP, i2o peer-to-peer, Ethernet/IP, or
Profinet depending on model number.
Ethernet Communication Controller
Innovasic RapID? Platform with PriorityChannel? for
determinism at the device regardless of network load.
Modbus TCP/IP (slave)
Port 502 reserved. Supports up to 10 sockets.
i2o Peer-to-Peer (master/slave)
Can map 4-channel input groups to output groups at
two destination IP addresses. Timed or change-of-state
updates. Supports GPRS/GSM systems.
Ethernet/IP (adapter)
Supports 16 connections. EDS file on website.
Profinet (server)
Supports 1 connection. GSDML file on website.
Connectors
Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.
Wiring
Auto-crossover for MDI or MDI-X.
IP Address
User-configurable. 128.1.1.100 default static IP address.
Data Rate
Auto-negotiated, 10Mbps or 100Mbps.
Compliance
IEEE 802.3, 802.3u, 802.3x.
■
Environmental
Operating temperature
-40 to 70°C (-40 to 158°F). Max temperature derates
-0.625°C per output channel at full load (300mA).
Storage temperature
-40 to 85°C (-40 to 185°F).
Relative humidity
5 to 95% non-condensing.
Power Requirement
12 to 32V DC (95mA maximum @ 24V).
Isolation
4-way isolation between I/O channels, network (each
port); and power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.
Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals
CE compliant. UL/cUL Class I; Div. 2 Zone 2.
■
Physical
General
General purpose plastic enclosure for mounting on
35mm “T-type” DIN rail.
Case Material
Self-extinguishing polyamide, UL94 V-0 rated, color
light gray. General purpose NEMA Type 1 enclosure.
Circuit Board
Military grade fire-retardant epoxy glass (IPC-4101/98).
I/O Connectors
Removable plug-in type terminal blocks rated for
12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions
Width = 22.5mm (0.9 inches), Length = 114.5mm
(4.51 inches), Depth = 99.0mm (3.90 inches).
Shipping Weight
0.5 pounds (0.22 Kg) packed.
Ordering Information
◆
Models
XT1121-000
Digitial I/O module, Modbus/TCP and i2o protocol.
XT1122-000
Digitial I/O module, Ethernet/IP protocol.
XT1123-000
Digitial I/O module, Profinet protocol.
◆
Software
XT-SIP
(
recommend one kit per customer
)
Software Interface Package. Includes software
(XT-CONFIG), isolator (USB-ISOLATOR), two USB cables
(4001-112, 4001-113), Ethernet cable (5035-360).
◆
Accessories
XTA-120V-6
XTA-240V-3
6-channel 120V AC/DC or 3-channel 240V AC/DC
discrete input module with 5V DC logic outputs.
Interfaces with sinking/sourcing DC Inputs.
XTA-MRNO-6
6-ch mechanical relay output module, Form A, SPST
normally open 5A relays (5/12/24V DC logic input).
XTBUS-KIT
DIN rail bus power/excitation connector kit. Includes
one DIN rail bus connector (1005-070), one left-side
female connector terminal block (1005-220) and one
right side male connector terminal block (1005-221).
USB-ISOLATOR
USB-to-USB isolator, includes USB cable (4001-112).
IMPORTANT: To prevent damage or errors from
grounded PCs and surges, Acromag strongly
recommends use of the USB-ISOLATOR when
configuring an XT1000 I/O module.
248-295-0880
■
248-624-9234
■
s
■
■
30765 Wixom Rd, Wixom, MI 48393 USA
Ethernet I/O: BusWorks
?
XT Series
Bulletin #8400-787c
Description
The XT1210 offers an isolated Ethernet network
interface for up to eight differential current input
channels. Isolated differential inputs deliver better
measurements, superior noise rejection, and
eliminate the need for current loop isolators.
Rugged construction, high density design, and
easy USB-to-PC/Windows setup combine for a
very effective and reliable module. These units
are ideal for remote monitoring, distributed
control, or SCADA applications.
Input Ranges
0 to 11mA, 0 to 20mA, 4 to 20mA, ±20mA.
0 to 20 amps AC (with optional AC sensor)
Ethernet Communication
Modbus TCP/IP, Ethernet/IP, Profinet,
i2o
?
peer-to-peer, 10/100Base-T(X)
PriorityChannel? device determinism
Power Requirement
12 to 32V DC (2.8W)
Key Features & Benefits
■
Easy setup with Windows software via USB
■
Low input impedance (27 ohms
)
reduces
loading on current loops
■
User-configurable sample averaging (1-200) on
a per-channel basis
■
10ms network updates for all 8 input channels
■
i2o peer-to-peer updates based on percent-of-
change and/or timed updates
■
High-resolution 16-bit
Σ-Δ
A/D converter
ensures precise, high accuracy measurements
■
High-Density 22.5mm wide package with
pluggable, front-facing terminals
■
Dual Ethernet 10/100 ports (auto-negotiation)
reduce switch port requir
ements
■
1500V AC isolation (between I/O, power, and
network ports) and surge/transient protection
■
Supports bussed/rail and redundant power
■
-40°C to +70°C wide temperature operation
■
Withstands 25g shock and 4g vibration
■
CE compliant. UL/cUL Class 1 Div 2 Zone 2
approval
8-channel differential analog current input
◆
Modbus TCP/IP, Ethernet/IP, Profinet, or i2o communication
XT1210
Ethernet Analog Current Input Modules
99.0
(3.90)
114.5
(4.51)
22.5
(0.89)
DIMENSIONS ARE IN MILLIMETERS (INCHES)
XT121x SIMPLIFIED I/O CHANNE
L
EXAMPLE INPUT CONNECTIONS
SOURCED DC CURRENT
IN0+
+
DC CURRENT
MILLIAMPS
TWO-WIRE CONNECTION
IN0-
RTN
+
-
IN0+
IN0-
RTN
+
ISOLATED
NETWORK PORTS
IN0+
IN0-
CH0
CH7
16-BIT
A/D
μC &
COMMS
ISOLATED
POWER
IN7+
IN7-
RTN
RTN
RTN
USB
Configured
BusWorks XT software (download free from ) allows you to configure I/O modules offline with
USB or save the configuration file and download settings into units later at your convenience.
248-295-0880
■
248-624-9234
■
s
■
■
30765 Wixom Rd, Wixom, MI 48393 USA
All trademarks are property of their respective owners. Copyright ? Acromag, Inc. 2014. Data subject to change without notice. Printed in USA 9/2014
Ethernet I/O: BusWorks
?
XT Series
XT1210
Ethernet Analog Current Input Modules
Performance Specifications
■
USB Interface
USB Connector
Type: USB Mini-B type socket, 5-pin.
Data rate: 12Mbps. USB v1.1 and 2.0 compatible.
Maximum cable length: 5.0 meters.
USB Transient Protection
Transient voltage suppression on power and data lines.
Driver
Not required. Uses Windows HID drivers.
■
Input
Accuracy
±0.05% of span, typical for nominal input ranges.
Analog to Digital Converter (A/D)
16-bit
Σ-Δ
converter. 1.476uA/bit resolution.
Noise Rejection
Better than -110dB @ 60Hz.
Input Filter Bandwidth
-3dB at 25KHz, typical.
Input Conversion Rate
10ms for all 8 input channels.
Input Impedance
27.4 ohms.
■
Ethernet Communication
Protocols
Modbus TCP/IP, i2o peer-to-peer, Ethernet/IP, or
Profinet depending on model number.
Ethernet Communication Controller
Innovasic RapID? Platform with PriorityChannel? for
determinism at the device regardless of network load.
Modbus TCP/IP (slave)
Port 502 reserved. Supports up to 10 sockets.
i2o Peer-to-Peer (master/slave)
Can map each of 8 analog input channels separay
to output channels. Timed (1-65535 sec) or percent-
of-change updates. Supports GPRS/GSM systems.
Ethernet/IP (adapter)
Supports 10 connections. EDS file on website.
Profinet (server)
Supports 1 connection. GSDML file on website.
Connectors
Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.
Wiring
Auto-crossover for MDI or MDI-X.
IP Address
User-configurable. 192.168.1.100 default IP address.
Data Rate
Auto-negotiated, 10Mbps or 100Mbps.
Compliance
IEEE 802.3, 802.3u, 802.3x.
■
Environmental
Operating temperature
-40 to 70°C (-40 to 158°F).
Storage temperature
-40 to 85°C (-40 to 185°F).
Relative humidity
5 to 95% non-condensing.
Power Requirement
12 to 32V DC, 2.8W maximum
(116mA maximum @ 24V).
Isolation
4-way isolation between I/O channels, network
(each port), and power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.
Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals
CE compliant. UL/cUL listed.
Designed for Class I; Division 2; Groups ABCD; Zone 2.
■
Physical
General
General purpose plastic enclosure for mounting on
35mm “T-type” DIN rail.
Case Material
Self-extinguishing polyamide, UL94 V-0 rated, color
light gray. General purpose NEMA Type 1 enclosure.
Circuit Board
Military grade fire-retardant epoxy glass (IPC-4101/98).
I/O Connectors
Removable plug-in type terminal blocks rated for
12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions
Width = 22.5mm (0.9 inches), Length = 114.5mm
(4.51 inches), Depth = 99.0mm (3.90 inches).
Shipping Weight
0.5 pounds (0.22 Kg) packed.
Ordering Information
◆
Models
XT1211-000
8-channel differential current input module,
Modbus/TCP and i2o protocol.
XT1212-000
8-channel differential current input module,
Ethernet/IP protocol.
XT1213-000
8-channel differential current input module,
Profinet protocol.
◆
Software
XT-SIP
(
recommend one kit per customer
)
Software Interface Package. Includes software
(XT-CONFIG), isolator (USB-ISOLATOR), two USB cables
(4001-112, 4001-113), Ethernet cable (5035-360).
◆
Accessories
XTBUS-KIT
DIN rail bus power/excitation connector kit. Includes
one DIN rail bus connector (1005-070), one left-side
female connector terminal block (1005-220) and one
right side male connector terminal block (1005-221).
USB-ISOLATOR
USB-to-USB isolator, includes USB cable (4001-112).
5020-350
AC current sensor (toroidal transformer).
Converts 0-20A AC to 0-11.17mA DC.
PS5R-SD24
Power supply (24V DC, 2.5A).
DIN RAIL 3.0
DIN RAIL 16.7
DIN rail strip, Type T, 3 inches (75mm) or
16.7 (425mm).
20RM-16-DIN
19” rack-mount kit with DIN rail.
IMPORTANT: To prevent damage or errors from
grounded PCs and surges, Acromag strongly
recommends use of the USB-ISOLATOR when
configuring an XT1000 I/O module.
248-295-0880
■
248-624-9234
■
s
■
■
30765 Wixom Rd, Wixom, MI 48393 USA
Ethernet I/O: BusWorks
?
XT Series
Bulletin #8400-788c
Description
The XT1220 offers an isolated Ethernet network
interface for up to eight differential voltage input
channels. Isolated differential inputs deliver better
measurements, superior noise rejection, and
eliminate the need for signal isolators.
Rugged construction, high density design, and
easy USB-to-PC/Windows setup combine for a
very effective and reliable module. These units
are ideal for remote monitoring, distributed
control, or SCADA applications.
Input Ranges
±5V, ±10V, 0 to 5V, 0 to 10V.
Ethernet Communication
Modbus TCP/IP, Ethernet/IP, Profinet,
i2o
?
peer-to-peer, 10/100Base-T(X)
PriorityChannel? device determinism
Power Requirement
12 to 32V DC (2.8W)
Key Features & Benefits
■
Easy setup with Windows software via USB
■
High input impedance (100K ohms
)
reduces
loading on voltage loops
■
User-configurable sample averaging (1-200) on
a per-channel basis
■
10ms network updates for all 8 input channels
■
i2o peer-to-peer updates based on percent-of-
change and/or timed updates
■
High-resolution 16-bit
Σ-Δ
A/D converter
ensures precise, high accuracy measurements
■
High-Density 22.5mm wide package with
pluggable, front-facing terminals
■
Dual Ethernet 10/100 ports (auto-negotiation)
reduce switch port requir
ements
■
1500V AC isolation (between I/O, power, and
network ports) and surge/transient protection
■
Supports bussed/rail and redundant power
■
-40°C to +70°C wide temperature operation
■
Withstands 25g shock and 4g vibration
■
CE compliant. UL/cUL Class 1 Div 2 Zone 2
approval
8-channel differential analog voltage input
◆
Modbus TCP/IP, Ethernet/IP, Profinet, or i2o communication
XT1220
Ethernet Analog Voltage Input Modules
99.0
(3.90)
114.5
(4.51)
22.5
(0.89)
DIMENSIONS ARE IN MILLIMETERS (INCHES)
XT122x SIMPLIFIED I/O CHANNE
L
EXAMPLE INPUT CONNECTIONS
DC VOLTAGE INPUT
IN0+
DC VOLTAG
E
IN0-
RTN
+
-
ISOLATED
NETWORK PORTS
IN0+
IN0-
CH0
CH7
16-BIT
A/D
μC &
COMMS
ISOLATED
POWER
IN7+
IN7-
RTN
RTN
RTN
USB
Configured
BusWorks XT software (download free from ) allows you to configure I/O modules offline with
USB or save the configuration file and download settings into units later at your convenience.
500 g
910 g
900 g
Tested:
TRSK 313
ADOS GmbH
Instrumentation
and Control
est. 1900
I
n
FRAR
e
D GAS A
n
ALYSIS SYST
em
The ITR 498 infrared gas analysis system
measures
continuously the concentration of carbon dioxid. This
gas has typical absorption bands in the infrared region
of radiation with which the exact concentration can be
determined. Typically used for measurements over the
range of 0–5.000 ppm to 0–100 Vol%.
The ITR 498 is available as: transmitter with current
output, as complete test unit with optical, acoustic and
electrical output as well as a hand-held tester.
Application
■
Monitoring the ventilation and air conditioning,
according to TRSK 313, for cellarage containing
carbon dioxide bottles
■
Monitoring the ventilation in fruit storage rooms
■
Regulating climatic conditions in large open-plan
offices or
departmental stores
■
Monitoring the maximum concentration at working
places,
according to TRGS 900 (MAC-value)
■
Monitoring carbon dioxide fire extinguishing systems
■
Analysing flue gases
■
Monitoring production processes
(e.g. fermenting processes)
■
Optimising chemical processes
■
and others
Fields of Application
The ADOS ITR 498 gas analysis
units function on the
principle of non-dispersive infrared absorption.
The wide-band infrared radiation generated by the
radiating element, passes through measurement and
reference filters, then on to the gas measuring vessel.
The measurement filter allows the passage of infrared
radiation in a wavelength range which includes the gas
absorption bands of the gas to be measured.
The reference filter on the other hand, allows the
passage of a wavelength range in which there are
no absorption bands of the gas.
From the absorption of the infrared radiation in the
measurement chamber, the concentration of the gas
is calculated and evaluated by a microcontroller.
m
ethod of Operation
Technical Data
Gas extraction, filter, gas purifier, gas cooler, signal horn,
warning lamps, warning banners, plotter, ventilation
control accessories.
Other accessories are available, depending on specific
measuring tasks, on request.
Accessories
GWA 2000
SINGLE-CHANNEL GAS WARNING SYSTEM
Instrumentation and Control
est.1900
ADOS GmbH
Instrumentation and Control
P.O. Box 500 444 · 52088 Aachen · FRG
Trierer Strasse 23-25 · 52078 Aachen · FRG
+
i
www.neck-heyn.de ? 01_2012
ADOS GmbH
Instrumentation
and Control
est.1900
The single-channel gas warning system GWA 2000
continuously monitors the ambient air and provides
an early warning of hazardous, explosive and
non-combustible gases and vapours.
Signal Horn, Warning Light, Warning Banner, Ventilation
Control, Test Meters, Plotter.
Additional accessories are available, depending on the
system ordered.
■
Monitoring of heating systems
■
Liquid gas stores rooms
■
Laboratories
■
Cold storage houses and air conditioning plants
■
Plastic processing plants
■
Chemical industries
■
Paint manufacturing plants
■
Concentration measurement of 0
2
■
and many more
■
Use of various types of measurement sensors
■
Ready, Fault and Gas warning indicators
■
Menu-aided operation, via 4 keys
■
Integrated buzzer
■
Three alarm thresholds individually adjustable
from 10 to 100
% of test range
■
Three floating alarm outputs for driving additional
warning and control systems
■
Floating contact connections for fault and
mains failure
■
Serial output, RS 232 for connecting a printer or a PC
■
High degree of reliability
■
Low energy consumption
■
Plastic wall-mounted housing
■
Easy installation
■
Straightforward operation
Application
Fields of Application
Features
Accessories
Hydrogen chloride
HCl
Methane (natural gas)
CH
4
Neon
Ne
Oxygen
O
2
Petroleum spirit
Propane
C
3
H
8
Toluene
C
7
H
8
Xylene
C
8
H
10
Sensors
:
Infrared sensor
Semiconductor sensor
Heat reaction sensor
Thermal conductivity sensor
Chemical sensor
Measurement
ranges:
CO: 0
–
300 ppm
NO
2
: 0
–
30 ppm
CH
4
:
0
–
100
% LEL
CO
2
: 0
–
10 Vol
%
further ranges of request
Accuracy:
< 3 % f.s.d.
Ambient temperature:
-10°C to +45°C
Temperature effects:
< 3 % for a ± 20 °C change
Setting time (t
90
):
< 60 s
Installation:
Wall-mounting
Protection class:
IP 54
Output signals:
RS 232 interface
3 Alarm relays
1 Fault relay
Analog output 4 (0) – 20 mA
Relay rating:
230 V, 450 VA
other voltages on request
Voltage supply:
230 V, 50 Hz
115 V, 60 Hz (optional)
24 V= (optional)
Power consumption:
14 VA
Dimensions (HxD):
200 x 160 x 90 mm
Weight:
approx. 1,6 kg
Technical Data
Gas
Formula
Acetylene
C
2
H
2
Alcohol
e.g. C
2
H
6
O
Ammonia
NH
3
Butane
C
4
H
10
Carbon dioxide
CO
2
Carbon monoxide
CO
Carbon tetrachloride
CCl
4
Chloroform
CHCI
3
Ether
C
4
H
10
O
Helium
He
Hydrogen
H
2
Measurable gases
SINGLE-CHANNEL GAS WARNING SYSTEM
GWA 2000
Filter-Guard 206
DUST FILTER MONITORING
Instrumentation and Control
est.1900
ADOS GmbH
Instrumentation and Control
P.O. Box 500 444 · 52088 Aachen · FRG
Trierer Strasse 23-25 · 52078 Aachen · FRG
+
i
www.neck-heyn.de · 01_2012
Measurement
principle:
optical light dispersion
Fields of application:
filtermonitoring for dry,
not sticking, not lumping,
not hygroscopic substances
Measurement ranges:
0
–
100
% dust
approx. measurement range:
total dust
0,1 – 20 mg/m
3
0,1 – 50 mg/m
3
0,1 – 100 mg/m
3
dependant on the kind of dust
at the measuring point
Medium humidity:
dry
Measurement
accuracy:
pure warning function,
no metering unit
Ambient temperature:
-10°C to +50°C
Response time (t
90
):
< 10 s
Installation:
flexible flange for output air
channel construction
(flat and round channels)
Protection class:
IP 54
Output signals:
analog output, 4 (0)
–
20 mA
RS 485
/
LON
?
Voltage supply:
24 V=
Power consumption:
3 VA
Dimensions (D x L):
50 x 300 mm or
50 x 600 mm (long version)
Weight:
approx. 0,95 kg
Trademark right:
EU-patent
Filter-Guard 206
continuously monitors the clean air side
of any fine dust filter installations.
A warning is initiated when a sudden increase in dust
concentration is present, i.e. due to breakdown in the
filter casing or bag.
Application
DUST FILTER MONITORING
Filter-Guard 206
■
Monitoring filter systems
■
Vibrating and jet filter systems
■
Air extraction installations in wood and
plastic processing plants
■
Air conditioning units with dust filter systems
■
Paint and varnish production
■
Ambient air monitoring at workplaces
■
and many more
Fields of Application
■
Suitable for various types of dust
■
4
–
20
mA standard output signal
■
LON
?
interface (optional)
■
Low current consumption
■
Robust aluminium housing
■
Straightforward installation
■
Easy exchange of the sensor elements
Features
Signal horns, warning lamps, warning banners,
air control accessories, metering units, plotters,
data-logger.
Further accessories can be supplied on request,
according to the proposed measurement tasks.
Accessories
Technical Data
Detectable Types of Dusts
Dry dusts:
■
Wood dust
■
Household dust
■
Colouring pigments
■
Plastic dust
■
Flour dust
■
Metallic dust
■
Mineral dust
■
and many more
Evaluation Units
Multi-channel installations:
MWS 897
MWS 903
LON
?
-Center 2000
GW 399
Multitronik MC 602
ADOS GmbH
Instrumentation
and Control
est.1900
Software
- Log & View Software
est.1900
R33_Sel_15_Pinout and setup guide R32R33R34_GTR_Basemap_15
Nissan Pulsar GTiR 240SX_Sel_pinout and setup guide 240SX_GTiR_Sel_Basemap
Nissan Skyline R34 GTT R34_Sel_pinout and setup guide R34_Sel_BaseMap
Suzuki Swift GTI Swift_Gti_Sel_pinout and setup guide GTI_Sel
Toyota MR2 SW20 SW20_MR2_Sel_pinout and setup guide sw20_Basemap
Previous Firmware Versions for Select and e420c ECUs
440_ECU_Mini
select pnp
Earlier versions & revision history
V.000 (2015-June-12)
Increase current output on injector drive (will have the effect of reducing the deadtime so people upgrading from V12 or 13 will need to recheck their tune).
Added compatibility with NTK AFRM on 0-5V input, and AEM on narrowband input with external voltage divider
Added imperial unit output for Race Technology dashes
Added enrichment persistence on transient throttle correction and made throttle change detection more sensitive
Added output for SRT4 dash
Added option to close idle valve when engine is on boost (for 1JZ VVTI engines)
Added variable dwell time
Added support for manual staging when injector sizes have been entered (VE mode or not)
V.000 (2014-Oct-17)
Added triggers for Rover Mini, Dodge SRT4, and crank-only trigger for LS1
Added ethanol percentage output on Race Technology output
Added specific rotary timing lock check for rotaries (leading @ 5°ATDC, 20°ATDC)
Added linear idle effort vs alternator load for NB MX5 / Miata
Added gentle pulsing of thermofan for less sudden electrical load for NB MX5 / Miata
Changed 3-level injector staging for wire-in ECUs so it behaves the same as on the RX8 plug-in
Added readback / verify for communications writes to fix map and boost control errors
V.000 (2014-Apr-10)
Arbitrary RPM / load spacing on fuel / ignition maps
Variable injection timing
Various trigger modes (improved Nissan, Mitsubishi Triton, Nissan M35/VQ35, xJZGTE VVTI
Higher resolution flex fuel tuning
Faster communications
Higher resolution TPS and MAP for logging / display
Innovate SSI4 input, oil, fuel pressure monitoring and engine protection
Various improvements in transient throttle (open loop fuel during transition, disable pump on constant throttle, additional async when cold)
PLX wideband input, PLX gauge output
Motec PLM input
Direct mode Race Technology output (no need for ECU interface now)
Basemaps and pinouts for for RX7 plug-in ECUs
Improved large plenum charger mode for supercharged engines, smoothness / antiflare on throttle off / upshifts
Individual percentage point ignition cut mode for smoother traction control
Twin turbo control / precontrol output for twin turbo RX7
Injector characterisation built-in for Injector Dynamics injectors
V10.000 (2011-Sep-07)
Added improved handling of missing tooth triggers on Select ECUs
Added software debouncing of VSS inputs on Select ECUs
Added oil metering control for Select ECUs
Support for additional plug-in Select ECUs
Additional RPM control algorithms for really large plenum engines (eg post-throttle supercharger and intercooler systems)
Added selectable MAP input filtering
Implemented crank angle period tracking for detecting trigger setup problems
Implemented automatic injector staging with VE tuning
Implemented automatic wasted spark on 4-cylinder direct fire engines until cam trigger is detected
Implemented 2nd serial port sharing to allow OBD/CAN interface and Innovate to share serial port
Added push-to-pass (scramble boost)
Added pit lane speed limiter
Added option to automatically detect neutral if no RPM matches the gear ratios
V9.000 (2010-Nov-02) (included in V10 download, no separate link)
Added ignition timing idle control option
Changed firmware to remove cylinder updating on SR20/RB2x above 2000 RPM, improved the stability of triggering on Nissans
Fixed Ign 4 (on Aux 1) behaviour at power-up
Fixed ‘ign crank’ triggering option with all ignition modes and forced only to operate on last trigger BTDC (so the Ign Crank option can now be used for all trigger patterns, to improve ignition timing stability at cranking)
V8.000 (2010-Sep-23)
Added a ‘Safe MAP’ variable to handle conditions where MAP sensor reading is invalid, now utilising the predicted MAP table for more than just transient throttle
Improved the stability of triggering on Nissans and Mazda RX-8s
Added secondary VSS functionality (so digital inputs 7 and 8 can be used as MVSS2 and SVSS2, only useful for traction control)
Fixed bug where having the same digital input type on multiple inputs didn’t act like an ‘OR’ (bug introduced in V7.000)
V7.000 (2010-Aug-30)
Added debouncing on A/C request input to help prevent on/off A/C cycling problem introduced with the delayed A/C output behaviour in V.000
Fixed up Holden V6 triggering
V.000 (2010-Jul-15)
Added delayed A/C output behaviour (approx 800ms hardcoded) to improve idle speed stability
Added another condition for the purge valve output where it will turn off when on boost
Further improved EEPROM code
V.000 (2010-Jun-11)
Fixed PRCV output
Fixed idle anti-windup when at max duty cycle (previously only worked on min duty cycle)
Further improved EEPROM code
Added ignition arbitration output on Inj 4, for Supra PnP loom only
Fixed VVT target angles based on 3D tables instead of 2D RPM tables
V.000 Removed from website straight away for commissioning.
V.000 (2010-Feb-25)
Improved robustness of code for communications between microcontroller and EEPROM chip, to better handle electrical interference, and prevent potential ECU resetting or settings corruption
Added Ignition Output test function (on ‘ECU Data’ window in WARI, with the Injector Test buttons)
V.000 (2009-Dec-15) – WARI Version .000
Added Volumetric Efficiency tuning
Added EGT-based aux outputs
Added ignition firing after TDC
Optimised Nissan 4 and 6 cylinder unique triggers, particularly for faster starting
Added optional filter with 1 second time constant for temperature inputs
Updated the idle control functionality (fixed A/C idle-up, enabled separate idle efforts to be added for different elec load inputs, changed the target RPM strategy to take the highest of the additional RPM values rather than the sum).
Added MAP prediction “drive by wire” mode for less sensitive throttle thresholds
Added ELM327 mode for once only at startup
Added 0-4V Autometer ES PRO calibration on external input
Added calibration for Jaycar KC5486 0-5V oxygen sensor on external input
Added calibration for Dynojet 0-5V oxygen sensor on external input
V.0Q (2009-Aug-17) – WARI Version V.13
Added MAP prediction for greatly improved and simplified transient throttle behaviour
V.0P (2009-Aug-10) – WARI Version V.12
Corrected tacho on aux output for 50% duty cycle
Added transient throttle ignition advance
Added logic-only inputs based on logic-only outputs
Added boost duty cycle scaling based on percent TPS
Removed ‘Enable Datalogging’ input feature
Added aux output based on battery voltage
Improved MAP and TPS resolution, now 1/16 of a kPa or Percent for interpolation
Removed MAP filter
Corrected bug with the closed-loop fuel max TPS
Added 2-rotor wasted leading, alternate/DF trailing mode
Added 2-rotor direct fire mode
Added ELM327 Scantool error correct mode @ 38400 baud
Added new tuning mode: 1=MAP, 2=MAP, Pri = 1, Sec = 1×2, Ign = 1
also added injector 3/4 trim (rear rotor trim), when in this tuning mode
Fixed bug with max RPM and max Load for closed-loop fuel control
Added min load for closed-loop fuel control
Fixed bug with WOT enrichment
Added special trigger mode for Nissan VQ30 engine
Added AEM UEGO 0-5V on spare input
Added protocol for Innovate TC-4 thermocouple interface device, on second serial port
Added support for Gen 5 Suzuki Swift triggering, with VVT and sequential injection
Improved accuracy of VVT angle detection
Added option for idle-up on each close throttle event (dashpot)
Fixed bug in TPS cutoff for asynch accelerator pump
Modified DC5 trigger mode to handle Yamaha XJR trigger
V.0N (2008-May-07) – WARI Version V.11
Traction control added
Launch control added
Changed aux output to correct hysteresis bug on general outputs (introduced in .0L) – now only does tighter limits on VVT functions
Modified Subaru 99-00 code to allow cam pulses to overlap crank pulses
Added control over maximum boost and duty cycle for each gear
Added gear learning
Added a maximum control authority for wastegate control
Added variable timeslice for idle control
Added sequential injection for NB MX5
Added ‘Enable datalogging’ digital input type, which forces the gauge data to be sent out through the first serial port (usually for laptop). This allows external dataloggers to read the serial signal
V.0M (2007-October-16) – WARI Version V.10
Divide by two with missing teeth trigger added
Aux out 4 inverse of Aux out 3 added for use with certain idle motors etc
Added AND and OR based outputs
Added Engine Make and Model selection
Added stored timing offset
Faster ADC
Faster throttle pump response
VSS code changed for greater accuracy
V.0L (2007-July-16) – WARI Version V.09
Reset on camshaft missing tooth added
A do not update already tuned for adaptive tuning modes added
Tacho on Aux output revised
Nissan trigger code optimised for higher rpm
Digital output revision for more tolerant operation (ie hysterisis, non exact values etc)
V.0J (2007-June-14) – WARI Version V.08
Added 2j Tech Edge wideband sensor
Added single and two cylinder engine configurations
Added coolant hi and low load enrichment
Improved ignition timing at very low rpm
V.0I (2007-May-16) – WARI Version V.07
Added coil addressAdaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Adaptronic
General Accessories
Showing 1–10 of 21 results
sair_IMG_0286a
Air Temperature Sensor
4.00 Add to cart
e440l_1_IMG_0270
e420d/440 long loom
89.00 Add to cart
single ignitor
Single Channel Ignitor
50.00 Add to cart
mac3_IMG_0290
3 Port Boost Control Valve
110.00 Add to cart
3 Bar Map Sensor
3 bar Map sensor
88.00 Add to cart
e440s_IMG_0272
e420d/440 short loom
68.00 Add to cart
e420c 2m Loom
e420c Standard long 2m loom
7.00 Add to cart
e440N_IMG_0306
e420d/440 connectors only
4.25 Add to cart
spress150_IMG_0287
150 PSI Pressure Sensor
20.50 Add to cart
GT1011-300x254
GT101 Gear Tooth Sensor
6.00 Add to cart
1
2
3
→
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Adaptronic
Showing 11–20 of 21 results
e420c short loom
e420c Standard short 0.5m loom
48.00 Add to cart
scool10_IMG_0298a1
Coolant Temperature Sensor
4.00 Add to cart
e420cN_IMG_0301
e420c Set of Connectors
20.00 Add to cart
stepper-motor
Stepper motor push-pull driver board
88.00 Add to cart
Boost Gauge
Boost Gauge
2.00 Add to cart
plxint_IMG_0293
PLX Interface Board with ECU Cable
6.00 Add to cart
m001_m003_IMG_0295
1 Bar MAP Sensor
88.00 Add to cart
pb-ecu-sharing-board
Piggy Back ECU Sharing Board
99.00 Add to cart
drive-by-wire
Drive-By-Wire driver board
16.00 Add to cart
Placeholder
Serial CAN Interface with ECU Cable
77.00 Add to cart
←
1
2
3
→
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Showing 21–21 of 21 results
Placeholder
1UZFE Defeater Board
60.01 Add to cart
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Injector Dynamics
Injector Dynamics
Showing 1–10 of 21 results
1000.60.11
ID1000cc, 60mm long, 11mm diameter
169.62 Add to cart
7.60.11
ID725cc, 60mm long, 11mm dia
169.62 Add to cart
1000.60.14
ID1000cc, 60mm long, 14mm diameter
169.62 Add to cart
id850 34mm x 14mm
ID850cc, 34mm long, 14mm dia (Copy)
169.62 Add to cart
ID1300-60-11
ID1300cc, 60mm long, 11mm diameter
318.04 Add to cart
ID1300-60-14
ID1300cc, 60mm long, 14mm diameter
318.04 Add to cart
2000.60.14
ID2000cc, 60mm long, 14mm dia
339.24 Add to cart
2000.48.14
ID2000cc, 48mm long, 14mm diameter
339.24 Add to cart
2000.60-11
ID2000cc, 60mm long, 11mm diameter
339.24 Add to cart
2000.48.11
ID2000cc, 48mm long, 11mm diameter
339.24 Add to cart
1
2
3
→
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Innovate Motorsports
Innovate Motorsports
Showing 1–10 of 57 results
accs-mtxl_all_web
Digital MTX-L Air/Fuel Ratio Gauge Kit (All-in-one) w/O2 Sensor
280.50 Add to cart
inn3877
LC-2: Lambda Cable Complete Kit w/Bosch O2 Sensor
270.63 Add to cart
Placeholder
Extended Bung/Plug Kit (Stainless Steel) 1 inch Tall
.30 Add to cart
Placeholder
6 Inch Patch Cable .5 mm
20.40 Add to cart
Placeholder
Inductive Clamp (LMA-2, LMA-3, DL-32 & LM-2)
48.62 Add to cart
Placeholder
TC-4 (4 Channel Thermocouple K-Type Amplifier)
19.05 Add to cart
Placeholder
SSI-4 (4 Channel Simple Sensor Interface)
19.05 Add to cart
Placeholder
Sensor (Bosch LSU .2)
120.12 Add to cart
Placeholder
Bung/Plug Kit (Mild Steel) 1/2 inch
.30 Add to cart
Placeholder
Sensor Cable: 3 ft. (LM-2, MTX-L)
4.90 Add to cart
1
2
3
4
5
6
→
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Injector Dynamics
Showing 11–20 of 21 results
ID2000-34
ID 2000cc, 34mm long, 14mm diameter
339.24 Add to cart
1000.48.14
ID1000cc, 48mm long, 14mm diameter
169.62 Add to cart
1000.48.11
ID1000cc, 48mm long, 11mm diameter
169.62 Add to cart
850.60.14
ID850cc, 60mm long, 14mm dia
169.62 Add to cart
850.48.14
ID850cc, 48mm long, 14mm dia
169.62 Add to cart
850.60.11
ID850cc, 60mm long, 11mm dia
169.62 Add to cart
850-48-11
ID850cc, 48mm long, 11mm dia
169.62 Add to cart
id850 34mm x 14mm
ID850cc, 34mm long, 14mm dia
169.62 Add to cart
725-60-14
ID725cc, 60mm long, 14mm dia
169.62 Add to cart
725-48-14
ID725cc,48mm long,14mm dia
169.62 Add to cart
←
1
2
3
→
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Innovate Motorsports
Showing 11–20 of 57 results
Placeholder
Extended Bung/Plug Kit (Titanium) 1 inch Tall
50.05 Add to cart
Placeholder
Program Cable: MTX Series
2.88 Add to cart
Placeholder
LM-2 “Basic Kit” Single Channel Wideband
499.07 Add to cart
Placeholder
Carrying Case LM-2
8.37 Add to cart
Placeholder
12mm to 18mm Motorcycle Bung Adapter
58.63 Add to cart
Placeholder
OT-2 Opentune OBD-II/CAN Interface w/LC-1 & O2 Sensor
.17 Add to cart
Placeholder
OT-2 Opentune OBD-II/CAN Wireless (WiFi) Interface
198.77 Add to cart
Placeholder
Sensor Cable: 18 ft. (LM-2, MTX-L)
118.69 Add to cart
Placeholder
LM-2 Window Mount
78.65 Add to cart
Placeholder
LM-2 USB Cable
1.44 Add to cart
←
1
2
3
4
5
6
→
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Injector Dynamics
Showing 21–21 of 21 results
ID725
ID 725cc, 48mm long, 11mm diameter
169.62 Add to cart
←
1
2
3
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Innovate Motorsports
Showing 21–30 of 57 results
Placeholder
LM-2 Serial Patch Cable
2.88 Add to cart
Placeholder
LM-2 Analog Cable
4.90 Add to cart
Placeholder
Sensor Cable: 8 ft. (LM-2, MTX-L)
7.93 Add to cart
Placeholder
LM-2 OBD-II Cable
4.90 Add to cart
Placeholder
LM-2 Power Cable
28.60 Add to cart
Placeholder
LM-2 Pro-V Dual Channel Wideband W/ OBDll
9.67 Add to cart
Placeholder
LM-2 Single Channel Wideband W/ OBD-ll
68.97 Add to cart
Placeholder
LC-1 Duo Kit (2 LC-1’s + DL-32)
1,08.62 Add to cart
Placeholder
LC-1 Plus Kit (LC-1 + SSI-4)
40.63 Add to cart
Placeholder
1 GB SD Card
3.46 Add to cart
←
1
2
3
4
5
6
→
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Innovate Motorsports
Showing 31–40 of 57 results
Placeholder
DL-32 (32 Channel Vehicle-Mounted Data-Logging System)
678.63 Add to cart
Placeholder
Extended Bung/Plug Kit (Mild Steel) 1 inch Tall (Incl; with all AFR kits)
.30 Add to cart
Placeholder
4 Ft. Patch Cable M.5 to M.5
20.40 Add to cart
Placeholder
Window Mount (LM-1 Only)
12.04 Add to cart
Placeholder
Terminator Plug
.25 Add to cart
Placeholder
Program Cable: LC-1, XD-1, Aux Box to PC
2.45 Add to cart
Placeholder
LMA-3: AuxBox (Multi-sensor Device)
.07 Add to cart
Placeholder
Serial Cable (LM-1 Only)
20.40 Add to cart
Placeholder
Power Cable Cigarette Lighter (LM-1 Only)
20.40 Add to cart
Placeholder
Sensor Cable 10 ft. (LM-1 Only)
.00 Add to cart
←
1
2
3
4
5
6
→
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Innovate Motorsports
Showing 41–50 of 57 results
Placeholder
Bung/Plug Kit (Stainless Steel) 1/2 inch
.30 Add to cart
Placeholder
USB-to-Serial Adapter
50.05 Add to cart
Placeholder
AC Power Adapter (LM-1 Only) —EOL—
5.04 Add to cart
Placeholder
HBX-1 (Heat-Sink Bung Extender)
127.27 Add to cart
Placeholder
Exhaust Clamp
118.69 Add to cart
Placeholder
Digital MTX-L Air/Fuel Ratio Gauge Kit (POWERSPORTS)
298.87 Add to cart
Placeholder
G5 (G5 Black Face Chrome Bezel Gauge)
148.72 Add to cart
Placeholder
G4 (G4 White Face Chrome Bezel Gauge)
148.72 Add to cart
Placeholder
G5 Kit (G5 Gauge, LC-1 & O2 Sensor)
370.37 Add to cart
Placeholder
G3 (G3 Gauge)
148.72 Add to cart
←
1
2
3
4
5
6
→
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Innovate Motorsports
Showing 51–57 of 57 results
Placeholder
G2 (G2 Gauge)
148.72 Add to cart
Placeholder
G3 Kit (G3 Gauge, LC-1 & O2 Sensor)
370.37 Add to cart
Placeholder
G2 Kit (G2 Gauge, LC-1 & O2 Sensor)
370.37 Add to cart
Placeholder
DB-Red Kit (Red LEDs, LC-1 & O2 Sensor)
3.17 Add to cart
Placeholder
DB-Blue Kit(Blue LEDs,LC-1 & O2 Sensor)
3.17 Add to cart
Placeholder
DB-Gauge Red (Gauge Only)
13.99 Add to cart
Placeholder
DB-Gauge Blue (Gauge Only)
13.99 Add to cart
←
1
2
3
4
5
6
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Zeitronix
Zeitronix
Showing all 5 results
FlexSensorFlowThrough_250
Flex Fuel Sensor
270.64 Add to cart
ECA2
Zeitronix ECA-2 Kit
379.00 Add to cart
Zeitronix Zt-3a
Zeitronix Lambda Sensor
227.50 Add to cart
Zeitronix Black Box
Zeitronix Black Box Logger Plus SD Card
14.00 Add to cart
Zeitronix Zt-3
Zeitronix Lambda Sensor / Gauge
270.64 Add to cart
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
Adaptronic
Adaptronic Engine Management
adaptronic youtube
adaptronic fb
About Us
FAQ
Support
Forum
Downloads
Articles
Contact Us
My Account ?
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Wall of Fame
0 items0.00
Race Technology
Race Technology Accessories
Showing all 5 results
dash2_pro_options_system
Dash 2 PRO Display w GPS / Logging
1,74.30 Add to cart
Dash2
RT Dash 2 Display
1,089.00 Add to cart
dash4pro_oled_lcd
RT Dash 4 Display
868.99 Add to cart
DASH3
RT Dash 3 Display
54.34 Add to cart
dl1_sport
DL1 Sport Data Logger
1,08.77 Add to cart
Which ECU is Right For Me?
FIND OUT MORE!
What is an ECU?
Choosing an ECU
ECUs
Accessories
Dealers
Privacy Policy
Terms and Conditions
About Us
FAQ
Support
Forum
Downloads
Contact Us
adaptronic logo
? 2013 Adaptronic.com.au
website security
ing output option (for RX7 series IV)
Added staged injection (2 and 4 are secondary injectors, modes 0, 1, 7)
Added 4th ignition output on Aux 1
Added FJO serial protocol
Added calmdown effort for idle
Added spark split
Added asynchronous pump cutoff
Load cell for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 30t to 500t
Class (OIML R60) C1 and C2
Combined Error: 0,023%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
C2S
Load cell for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 100 kg to 200 tons
Class (OIML R60) C1, C2 and C3
Combined Error: 0,023%
Output: 2mV/V
On request
REQUEST A FREE QUOTATION
Read more...
C2S-AMP
Load cell for the measurement of static loads in COMPRESSION.
Nominal Load from 100 kg to 200 tons
linearity andhysteresis 0.03%
REQUEST A FREE QUOTATION
Read more...
CBS
Load cell for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 250 kg to 100 tons
Combined Error: 0,03%
Output: 2mV/V
LOW COST version produced for over 30 years.
REQUEST A FREE QUOTATION
Read more...
FT2
SHEAR BEAM load cell for the measurement of static and dynamic loads.
Nominal Load from 500 kg to 10 tons
Class (OIML R60) C2 and C3
Combined Error: 0,019%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
FT1
SHEAR BEAM load cell for the measurement of static and dynamic loads.
Nominal Load from 350 kg to 7,5 tons
Class (OIML R60) C2 and C3
Combined Error: 0,020%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
F3
BENDING BAEM load cell for the measurement of static and dynamic loads.
Nominal Load from 10 kg to 2 tons
Class (OIML R60) C2 and C3
Combined Error: 0,018%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
F1
BENDING BAEM load cell for the measurement of static and dynamic loads.
Nominal Load from 2,5 kg to 200 kg
Class (OIML R60) C2 and C3
Combined Error: 0,020%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
FT6
OFF CENTER load cell for the measurement of static and dynamic loads.
Nominal Load from 5 kg to 100 kg
Class (OIML R60) C2
Combined Error: 0,028%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
TS-AMP
Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION.
Nominal Load from 10 kg to 10 tons
linearity and hysteresis 0,030%
Standar output M12 connector
REQUEST A FREE QUOTATION
Read more...
TS
Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION.
Nominal Load from 10 kg to 10 tons
Class (OIML R60) C2, C3 and C4
Combined Error: 0,018%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
CLT
Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION.
Nominal Load from 100 tons to 250 tons
Linearity: 0,10%
Output: 2mV/V
on request
REQUEST A FREE QUOTATION
Read more...
D200
Load cell for the measurement of static and dynamic loads in TENSION
Nominal Load from 20 tons to 100 tons
Linearity: 0,10%
Output: 2mV/V
on request
REQUEST A FREE QUOTATION
Read more...
T20-AMP
Load cell for the measurement of static loads in TENSION.
Nominal Load from 5 tons to 20 tons
Linearity and Hysteresis 0.03%
Standar output M12 connector
REQUEST A FREE QUOTATION
Read more...
T20
Load cell for the measurement of static and dynamic loads in TENSION.
Nominal Load from 5 tons to 20 tons
Class (OIML R60) C2 and C3
Combined Error: 0,019%
Output: 2mV/V
on request
REQUEST A FREE QUOTATION
Read more...
TCE-AMP
Load cell for the measurement of static loads in COMPRESSION and TENSION.
Nominal Load from 350 tons to 20 tons
Linearity and Hysteresis 0.03%
Standar output M12 connector
REQUEST A FREE QUOTATION
Read more...
TCE
Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 350 kg to 20 tons
Linearity and Hysteresis 0.03%
Output: 2mV/V
on request
REQUEST A FREE QUOTATION
Read more...
TCA
Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 1 kg to 50 kg
Linearity and Hysteresis 0.03%
Output: 2mV/VProfessional ergonomic indicator extremely versatile and easy to be used for measurement of FORCE, WEIGHT, PRESSURE (gas), VACUUM, TORQUE and DISPLACEMENT.
It is possible to integrate inside a FORCE sensor from 10 N to 5 kN or a pressure sensor (relative, absolute or differential up to max. 5bar) while from the external input it is possible to connect strain gauges sensors with output in mV/V such as: load cells, force transducers, pressure transducers, torque and displacement transducers.
AUTOMATIC recognition of FORCE, WEIGHT, VACUUM, PRESSURE, TORQUE and DISPLACEMENT external transducers (max. 7)
LCD graph DISPLAY with 3 levels of backlighting to adapt itself to any conditions of external brightness and with the possibility of rotating the visualization of 180°.
DIGITAL CALIBRATIONS protected by Password with full scale programming or with the “LINEARIZATION by points” of transducers, for every transducer it is possible to separay calibrate both the positive and the negative field. (Example: Tension and Compression)
DATALOGGER allows to memorize measurements and to keep them in the internal memory even in case of instrument switching off. (max. 130.000 recordings)
REQUEST A FREE QUOTATION
Read more...
CLF
Force transducers for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 300 kN to 5 MN
Class (ISO 376) 1
Linearity and Hysteresis 0,05%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
CLFlex
The transducer consists of a STRAIN CYLINDER and a FORCE transducer used for the calibration and auto alignment of the joints as well as for the force centering of compression test machines on hardened concrete.
Executed according to the norm references: UNI EN 12390-4 and DIN 51302-.
Nominal Load 3 MN
Class (ISO 376) 1
Linearity and Hysteresis 0,05%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
CLB
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 30 kN to 600 kN
Class (ISO 376) 00, 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
KAL
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 10 kN to 1 MN
Class (ISO 376) 00, 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
microKAL
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 50 N to 5 kN
Class (ISO 376) 00, 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
TCETM
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 5 kN to 100 kN
Class (ISO 376) 00, 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
TSTM
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 500 N to 5 kN
Class (ISO 376) 00, 0.5 and 1
Linearity and Hysteresis 0,025%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
C8S
Force transducers for the measurement of static and dynamic loads in COMPRESSION
Nominal Load from 5 kN to 1 MN
Class (ISO 376) 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V
REQUEST A FREE QUOTATION
Read more...
TC4
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 5 kN to 5 MN
Class (ISO 376) 1
Linearity and Hysteresis 0,05%
Output: 2mV/V
on request
REQUEST A FREE QUOTATION
Read more...
DC-TC4
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 10 kN to 1 MN
Linearity and Hysteresis 0.05%
INTEGRATED DIGITAL INDICATOR
Functions ZERO, PEAK, Digital FILTER Programmable.
REQUEST A FREE QUOTATION
Read more...
DCV-TC4
orce transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 10 kN to 1 MN
Linearity and Hysteresis 0.05%
INTEGRATED DIGITAL INDICATOR
ZERO function
REQUEST A FREE QUOTATION
Read more...
TC4-AMP
Force transducers for the measurement of static loads in COMPRESSION and TENSION
Nominal Load from 5 kN to 5 MN
Linearity and Hysteresis 0,05%
Standar output
REQUEST A FREE QUOTATION
Read more...
TC8
Force transducers for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 10 kN to 1 MN
Class (ISO 376) 0.5 and 1
Linearity and Hysteresis 0,03%
Output: 2mV/V
on request
REQUEST A FREE QUOTATION
Read more...
C10
Force transducers for the measurement of static and dynamic loads in COMPRESSION an TENSION
Nominal Load from 10 kN to 1 MN
Linearity and Hysteresis 0,05%
Standard Output
REQUEST A FREE QUOTATION
Read more...
CM
Force transducers with SMALL SIZE for the measurement of static and dynamic loads in COMPRESSION
Nominal Load from 100 kg to 5 tons
Linearity and Hysteresis 0,20%
Standard Output Torque transducers
torsiometri
Designing and production of STATIC and ROTATING torque transducers according to the norms EA 10-1
Ranges from 0.5 N·m up to 5000 N·m
Precision classes from 0.03% up to 0.20%
Analog and Digital Output: 2mV/V, ±10Volt and USB
Versions with reading ANGLE and SPEED integrated..
TRX
STATRIC torque transducers for the measurement in clockwise and anticlockwise direction
FLANGE process coupling
Nominal torque from 50 N?m to 5000 N?m
Class (EURAMER cg-14) 0.05 and 0.1
Linearity and Hysteresis 0,03%
Output: 1mV/V
HIGH ACCURACY
REQUEST A FREE QUOTATION
Read more...
RT2
ROTATING torque transducers for the measurement in clockwise and anticlockwise direction
CYLINDRICAL or SQUARE coupling
Nominal torque from 0.5 N?m to 5000 N?m
Linearity and Hysteresis 0,20%
Nominal speed of rotation 4000 rpm
Contact transmission
RT2 standard outut ±2mV/V
RT2A standard output ±10Volt
REQUEST A FREE QUOTATION
Read more...
RT2-USB
ROTATING torque transducers for the measurement in clockwise and anticlockwise direction
CYLINDRICAL or SQUARE coupling
Nominal torque from 0.5 N?m to 5000 N?m
Linearity and Hysteresis 0,20%
Nominal speed of rotation 4000 rpm
Contact transmission
Versions with integrated reading ANGLE and SPEED
Digital Output
REQUEST A FREE QUOTATION
Read more...
EasyTORK
ROTATING torque transducers for the measurement in clockwise and anticlockwise direction
HEXAGONAL coupling whit quick action chuck
Nominal torque 5 N?m, 10 N?m and 25 N?m
Linearity and Hysteresis 0,20%
Nominal speed of rotation 4000 rpm
Contact transmission
Versions with integrated reading ANGLE and SPEED
Digital Output
Read more...
microTOR
ROTATING torque transducers for the measurement in clockwise and anticlockwise direction
HEXAGONAL coupling whit quick action chuck
Nominal torque 5 N?m, 10 N?m and 25 N?m
Linearity and Hysteresis 0,20%
Nominal speed of rotation 4000 rpm
Contact transmission
Output 2 mV/V
VERY COMPACT SIZE
REQUEST A FREE QUOTATION
Read more...
TRS
STATRIC torque transducers for the measurement in clockwise and anticlockwise direction
SQUARE drive process coupling (UNI ISO 1174-1)
Nominal torque from 0,5 N?m to 1000 N?m
Linearity and Hysteresis 0,2% or 0.1%
Output: 2mV/V
LOW PRICE and EASY APPLICATIONS
REQUEST A FREE QUOTATION
Read more...
BTR
DESKTOP DIGITAL TORQUE forthe measurement in clockwise and anticlockwise direction
For calibrate of torque keys and torque screwdrivers
SQUARE drive process coupling (UNI ISO 1174-1)
Nominal torque from 0,5 N?m to 2000 N?m
Linearity and Hysteresis 0,20%
Output RS232 on request
LOW PRICE and EASY APPLICATIONS
REQUEST A FREE QUOTATION
Read more...
ATC
Manual drive for the calibration of torque KEY wrenches
ATC1000 for torque key whit max. ful scale 1000 N?m
ATC2000 for torque key whit max. ful scale 2000 N?m
REQUEST A FREE QUOTATION
Read more...
DTR
Hand held digital indicator, totally autonomous and with input for strain gauge based torque transducers.
It is ideal to be used in the most modern static and dynamic measurement systems.
With 0,02% accuracy makes it possible to be used use in quality systems as first or second line sample, periodically calibrated by a calibration centre (ACCREDIA in italy).
REQUEST A FREE QUOTATION
Read more...
STAR-T
Professional ergonomic indicator extremely versatile and easy to be used for measurement of FORCE, WEIGHT, PRESSURE (gas), VACUUM, TORQUE and DISPLACEMENT.
It is possible to integrate inside a force sensor (up to max. 5kN) or a pressure sensor (relative, absolute or differential up to max. 5bar) while from the external input it is possible to connect strain gauges sensors with output in mV/V such as: load cells, force transducers, pressure transducers, torque and displacement transducers.
AUTOMATIC recognition of FORCE, WEIGHT, VACUUM, PRESSURE, TORQUE and DISPLACEMENT external transducers (max. 7)
LCD graph DISPLAY with 3 levels of backlighting to adapt itself to any conditions of external brightness and with the possibility of rotating the visualization of 180°.
DIGITAL CALIBRATIONS protected by Password with full scale programming or with the “LINEARIZATION by points” of transducers, for every transducer it is possible to separay calibrate both the positive and the negative field. (Example: Tension and Compression)
DATALOGGER allows to memorize measurements and to keep them in the internal memory even in case of instrument switching off. (max. 130.000 recordings)
Displacement transducers
Designing and production of strain gauge linear DISPLACEMENT transducers.
Nominal displacements from 5mm to 100mm.
Suitable for industrial, laboratory and geotechnical applications.
LDT
Displacement transducers for linear measurement
Nominal displacement from 5 mm to 100 mm
Linearity and Hysteresis 0,10%
LDT standar output 2mV/V
LDTA standard output 0,5 - 5,5Volt
LOW COST and EASY APPLITATIONS
REQUEST A FREE QUOTATION Pressure transducers
trasduttori
Designing and production of straingauge pressure transducers with ranges from 0.1 up to 2500 bar
Version for RELATIVE, ABSOLUTE, VACUUM and DIFFERENTIAL measures.
With amplified or non-amplified output.
Precision classes from .0% up to 0.05%.
high reliability.
DF2R
DIFFERENTIAL pressure transducers
Nominal pressures from 100 mbar to 15 bar
AMPLIFIED outputs: ±10Volt
Linearity and hysteresis 0,10%
REQUEST A FREE QUOTATION
Read more...
DF2
DIFFERENTIAL pressure transmitter
Nominal pressures from 0,5 bar to 2000 bar
AMPLIFIED outputs: 4-20mA, 10V or 5Volt
Linearity and hysteresis 0,20%
REQUEST A FREE QUOTATION
Read more...
TPL2C
Pressure transmitters to permanent IMMERSION for level measures
Nominal RELATIVE pressures from 300mbar (3mH2O) to 20bar (200mH2O)
AMPLIFIED output 4-20mA 2 wires
Linearity and Hysteresis 0,10%
REQUEST A FREE QUOTATION
Read more...
TP8
Pressure transducers for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 5 bar to 1000 bar
Output 2mV/V
Linearity and hysteresis 0,50%
PROTRUDING DIAPHRAGM
HIGH TEMPERATURE max. 150 ° C
REQUEST A FREE QUOTATION
Read more...
TP7DN
Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 1 bar to 50 bar
AMPLIFIED outputs: 4-20mA, 10V or 5Volt
Linearity and hysteresis 0,50%
PROTRUDING DIAPHRAGM
REQUEST A FREE QUOTATION
Read more...
TP15
Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 1 bar to 50 bar
AMPLIFIED outputs: 4-20mA, 10V or 5Volt
Linearity and hysteresis 0,50%
PROTRUDING DIAPHRAGM
REQUEST A FREE QUOTATION
Read more...
TP1
Pressure transducers for RELATIVE and ABSOLUTE measures
Nominal pressures from 10 bar to 700 bar
Linearity and hysteresis 0,20%
TP1 standard output 2mV/V
TP1A amplified ouput 0,5-5,5 Volt
REQUEST A FREE QUOTATION
Read more...
TP16
Pressure transducers for RELATIVE and ABSOLUTE measures
Nominal pressures from 5 bar to 2000 bar
Output 2mV/V
Linearity and hysteresis 0,10%
REQUEST A FREE QUOTATION
Read more...
TP38
Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 100 mbar to 2000 bar
AMPLIFIED outputs: 4-20mA, 10V and 5Volt
Linearity and hysteresis 0,25%, 0.50% or 1%
LOW COST
REQUEST A FREE QUOTATION
Read more...
TP18
Pressure transmitters for RELATIVE and ABSOLUTE measures
Nominal pressures from 5 bar to 2500 bar
AMPLIFIED outputs: 4-20mA, 10V or 5Volt
Linearity and hysteresis 0,20%
HIGH TEMPERATURE max. 150 ° C
REQUEST A FREE QUOTATION
Read more...
TPUSB
Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 100 mbar to 2000 bar
Linearity and hysteresis 0,10% or 0.05%
Digital Output
REQUEST A FREE QUOTATION
Read more...
TP3
Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 100 mbar to 2000 bar
AMPLIFIED outputs: 4-20mA, 10V or 5Volt
Linearity and hysteresis 0,50%
REQUEST A FREE QUOTATION
Read more...
TP12
Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 100 mbar to 2000 bar
AMPLIFIED outputs: 4-20mA, 10V or 5Volt
Linearity and hysteresis 0,20%
REQUEST A FREE QUOTATION
Read more...
TP14
Pressure transmitters for RELATIVE, ABSOLUTE and VACUUM measures
Nominal pressures from 100 mbar to 2000 bar
AMPLIFIED outputs: 4-20mA, 10V or 5Volt
TP14 Linearity and hysteresis 0,10%
LabTP14 Linearity and hysteresis 0,05%
REQUEST A FREE QUOTATION Pressure gauges
Design and production of digital pressure gauges with ranges from 0.1 up to 2500 bar.
Version for RELATIVE, ABSOLUTE, VACUUM and DIFFERENTIAL measures.
Precision classes from 0.5% up to 0.05%.
available with high resolutions
Internal batteries.
High reliability
STAR-P
Professional ergonomic indicator extremely versatile and easy to be used for measurement of FORCE, WEIGHT, PRESSURE (gas), VACUUM, TORQUE and DISPLACEMENT.
Pressure transducers INSIDE
Coupling: 1/8" GAS Female
RELATVE pressures from 100 mbar to 5 bar
ABSOLUTE pressures from 500 mbar to 5 bar (barometric pressure)
DIFFERENTIAL pressures from 100 mbar to 5 bar
OPERATES UNTIL 7 EXTERNAL SENSORS with ABSOLUTE pressures from 5 bar to 2000 bar
Programmable DATA LOGGER
Accuracy: 0,10% and 0,05%
Applications in GAS and AIR (NO liquids)
USB output
REQUEST A FREE QUOTATION
Read more...
JET
Digital pressure gauges for RELATIVE, ABSOLUTE and VACCUM measures
Nominal pressures from 100 mbar to 2000 bar
Linearity and hysteresis 0,20%
Measurement of the temperature of the fluid
High mechanical strength
Suitable for dynamic and static applications
Funzioni: ZERO, FILTRO, PICCO, AUTO SPEGNIMENTO
Programmable DATA LOGGER
Record PRESSURE and TEMPERATURE
USB Outpur WIRELESS version on request
REQUEST A FREE QUOTATION
Read more...
LabDMM
Digital pressure gauges for RELATIVE and VACCUM measures
Nominal pressures from 1 bar to 2000 bar
Linearity and hysteresis 0,05%
High mechanical strength
Suitable for dynamic and static applications
HIGH ACCURACY
REQUEST A FREE QUOTATION
Read more...
IDROSCAN
Digital pressure gauges for RELATIVE and VACCUM measures
Nominal pressures from 1 bar to 2000 bar
Linearity and hysteresis 0,20%
Measurement of the temperature of the fluid
High mechanical strength
Suitable for dynamic and static applications
Programmable DATA LOGGER
Record PRESSURE and TEMPERATURE
REQUEST A FREE QUOTATION
Read more...
Bit02B
Digital pressure gauges for RELATIVE and VACCUM measures
Nominal pressures from 1 bar to 2000 bar
Linearity and hysteresis 0,20%
Measurement of the temperature of the fluid
High mechanical strength
Suitable for dynamic and static applications
LOW COST
REQUEST A FREE QUOTATION
Read more...
Bit02D
Digital pressure gauges for DIFFERENTIAL measures
Nominal pressures from 10 bar to 700 bar
Linearity and hysteresis 0,20%
High mechanical strength
Suitable for dynamic and static applications
System composed of a Bit02B and 2 pressure transducers type TP1
REQUEST A FREE QUOTATION
Read more...
PGE
Digital pressure gauges for RELATIVE and VACCUM measures
Nominal pressures from 1 bar to 2000 bar
Linearity and hysteresis 0,50%
Measurement of the temperature of the fluid
High mechanical strength
Suitable for dynamic and static applications
LOW COST
REQUEST A FREE QUOTATION
Read more...
DFP
Digital pressure gauges for RELATIVE measures
Nominal pressures from 10 bar to 2000 bar
Linearity and hysteresis 0,10%
High mechanical strength
Suitable for dynamic and static applications
Ability to view both the FORCE and the PRESSURE push of a cylinder
REQUEST A FREE QUOTATION
Read more...
DMM
Digital pressure gauges for RELATIVE and VACCUM measures
Nominal pressures from 1 bar to 2000 bar
Linearity and hysteresis 0,15%
High mechanical strength
Suitable for dynamic and static applications
No. 2 SET POINT programmable with output relays output
REQUEST A FREE QUOTATION
Read more...
DMMD
Digital DIFFERENTIAL pressure gauges for RELATIVE measures
Nominal pressures from 1 bar to 2000 bar
Linearity and hysteresis 0,15%
High mechanical strength
Suitable for dynamic and static applications
No. 2 SET POINT programmable with output relays output
REQUEST A FREE QUOTATION
Read more...
DME
Digital pressure gauges for RELATIVE measures
Nominal pressures from 1 bar to 2000 bar
Linearity and hysteresis 0,20%
High mechanical strength
Suitable for dynamic and static applications
No. 2 SET POINT programmable with output relays outp
u
R
e
M
en
T
, C